Molecular & Cellular Proteomics 4:1180-1188, 2005.
© 2005 by The American Society for Biochemistry and Molecular Biology, Inc.

From the Laboratory for Biological and Medical Mass Spectrometry, Uppsala University, S-75123 Uppsala, Sweden
The Mascot score (M-score) is one of the conventional validity measures in data base identification of peptides and proteins by MS/MS data. Although tremendously useful, M-score has a number of limitations. For the same MS/MS data, M-score may change if the protein data base is expanded. A low M-value may not necessarily mean poor match but rather poor MS/MS quality. In addition M-score does not fully utilize the advantage of combined use of complementary fragmentation techniques collisionally activated dissociation (CAD) and electron capture dissociation (ECD). To address these issues, a new data base-independent scoring method (S-score) was designed that is based on the maximum length of the peptide sequence tag provided by the combined CAD and ECD data. The quality of MS/MS spectra assessed by S-score allows poor data (39% of all MS/MS spectra) to be filtered out before the data base search, speeding up the data analysis and eliminating a major source of false positive identifications. Spectra with below threshold M-scores (poor matches) but high S-scores are validated. Spectra with zero M-score (no data base match) but high S-score are classified as belonging to modified sequences. As an extension of S-score, an extremely reliable sequence tag was developed based on complementary fragments simultaneously appearing in CAD and ECD spectra. Comparison of this tag with the data base-derived sequence gives the most reliable peptide identification validation to date. The combined use of M- and S-scoring provides positive sequence identification from >25% of all MS/MS data, a 40% improvement over traditional M-scoring performed on the same Fourier transform MS instrumentation. The number of proteins reliably identified from Escherichia coli cell lysate hereby increased by 29% compared with the traditional M-score approach. Finally S-scoring provides a quantitative measure of the quality of fragmentation techniques such as the minimum abundance of the precursor ion, the MS/MS of which gives the threshold S-score value of 2.
To whom correspondence should be addressed: Laboratory for Biological and Medical Mass Spectrometry, Uppsala University, Box 583, S-75123 Uppsala, Sweden. Tel.: 46-18-471-5729; Fax: 46-18-471-5729; E-mail: Mikhail.Savitski{at}bmms.uu.se
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
M. Brosch, S. Swamy, T. Hubbard, and J. Choudhary Comparison of Mascot and X!Tandem Performance for Low and High Accuracy Mass Spectrometry and the Development of an Adjusted Mascot Threshold Mol. Cell. Proteomics, May 1, 2008; 7(5): 962 - 970. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Stead, N. W. Paton, P. Missier, S. M. Embury, C. Hedeler, B. Jin, A. J. P. Brown, and A. Preece Information quality in proteomics Brief Bioinform, March 1, 2008; 9(2): 174 - 188. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Bouyssie, A. G. de Peredo, E. Mouton, R. Albigot, L. Roussel, N. Ortega, C. Cayrol, O. Burlet-Schiltz, J.-P. Girard, and B. Monsarrat Mascot File Parsing and Quantification (MFPaQ), a New Software to Parse, Validate, and Quantify Proteomics Data Generated by ICAT and SILAC Mass Spectrometric Analyses: Application To the Proteomics Study of Membrane Proteins from Primary Human Endothelial Cells Mol. Cell. Proteomics, September 1, 2007; 6(9): 1621 - 1637. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Lerner, M. Corcoran, D. Cepeda, M. L. Nielsen, R. Zubarev, F. Ponten, M. Uhlen, S. Hober, D. Grander, and O. Sangfelt The RBCC Gene RFP2 (Leu5) Encodes a Novel Transmembrane E3 Ubiquitin Ligase Involved in ERAD Mol. Biol. Cell, May 1, 2007; 18(5): 1670 - 1682. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Bandeira, D. Tsur, A. Frank, and P. A. Pevzner Protein identification by spectral networks analysis PNAS, April 10, 2007; 104(15): 6140 - 6145. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. L. Nielsen, M. M. Savitski, and R. A. Zubarev Extent of Modifications in Human Proteome Samples and Their Effect on Dynamic Range of Analysis in Shotgun Proteomics Mol. Cell. Proteomics, December 1, 2006; 5(12): 2384 - 2391. [Abstract] [Full Text] [PDF] |
||||
![]() |
Q. C. Ru, L. A. Zhu, J. Silberman, and C. D. Shriver Label-free Semiquantitative Peptide Feature Profiling of Human Breast Cancer and Breast Disease Sera via Two-dimensional Liquid Chromatography-Mass Spectrometry Mol. Cell. Proteomics, June 1, 2006; 5(6): 1095 - 1104. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. Savitski, M. L. Nielsen, and R. A. Zubarev ModifiComb, a New Proteomic Tool for Mapping Substoichiometric Post-translational Modifications, Finding Novel Types of Modifications, and Fingerprinting Complex Protein Mixtures Mol. Cell. Proteomics, May 1, 2006; 5(5): 935 - 948. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. I. Nesvizhskii, F. F. Roos, J. Grossmann, M. Vogelzang, J. S. Eddes, W. Gruissem, S. Baginsky, and R. Aebersold Dynamic Spectrum Quality Assessment and Iterative Computational Analysis of Shotgun Proteomic Data: Toward More Efficient Identification of Post-translational Modifications, Sequence Polymorphisms, and Novel Peptides Mol. Cell. Proteomics, April 1, 2006; 5(4): 652 - 670. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Salmi, R. Moulder, J.-J. Filen, O. S. Nevalainen, T. A. Nyman, R. Lahesmaa, and T. Aittokallio Quality classification of tandem mass spectrometry data Bioinformatics, February 15, 2006; 22(4): 400 - 406. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. V. Olsen, L. M. F. de Godoy, G. Li, B. Macek, P. Mortensen, R. Pesch, A. Makarov, O. Lange, S. Horning, and M. Mann Parts per Million Mass Accuracy on an Orbitrap Mass Spectrometer via Lock Mass Injection into a C-trap Mol. Cell. Proteomics, December 1, 2005; 4(12): 2010 - 2021. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| All ASBMB Journals | Journal of Biological Chemistry |
| Journal of Lipid Research | ASBMB Today |