Originally published In Press as doi:10.1074/mcp.M500339-MCP200 on April 23, 2006.
Molecular & Cellular Proteomics 5:1326-1337, 2006.
© 2006 by The American Society for Biochemistry and Molecular Biology, Inc.
Research
Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun Proteomics*,S
Wilhelm Haas ,
Brendan K. Faherty ,
Scott A. Gerber ,
Joshua E. Elias ,
Sean A. Beausoleil ,
Corey E. Bakalarski ,
Xue Li ,
Judit Villén and
Steven P. Gygi , ,¶
From the Department of Cell Biology and Taplin Biological Mass Spectrometry Facility, Harvard Medical School, Boston, Massachusetts 02115
Mass spectrometers that provide high mass accuracy such as FT-ICR instruments are increasingly used in proteomic studies. Although the importance of accurately determined molecular masses for the identification of biomolecules is generally accepted, its role in the analysis of shotgun proteomic data has not been thoroughly studied. To gain insight into this role, we used a hybrid linear quadrupole ion trap/FT-ICR (LTQ FT) mass spectrometer for LC-MS/MS analysis of a highly complex peptide mixture derived from a fraction of the yeast proteome. We applied three data-dependent MS/MS acquisition methods. The FT-ICR part of the hybrid mass spectrometer was either not exploited, used only for survey MS scans, or also used for acquiring selected ion monitoring scans to optimize mass accuracy. MS/MS data were assigned with the SEQUEST algorithm, and peptide identifications were validated by estimating the number of incorrect assignments using the composite target/decoy database search strategy. We developed a simple mass calibration strategy exploiting polydimethylcyclosiloxane background ions as calibrant ions. This strategy allowed us to substantially improve mass accuracy without reducing the number of MS/MS spectra acquired in an LC-MS/MS run. The benefits of high mass accuracy were greatest for assigning MS/MS spectra with low signal-to-noise ratios and for assigning phosphopeptides. Confident peptide identification rates from these data sets could be doubled by the use of mass accuracy information. It was also shown that improving mass accuracy at a cost to the MS/MS acquisition rate substantially lowered the sensitivity of LC-MS/MS analyses. The use of FT-ICR selected ion monitoring scans to maximize mass accuracy reduced the number of protein identifications by 40%.
¶ To whom correspondence should be addressed. Tel.: 617-432-3155; Fax: 617-432-1144; E-mail: steven_gygi{at}hms.harvard.edu

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati What's this?
This article has been cited by other articles:

|
 |

|
 |
 
Y. Abe, S.-O. Yoon, K. Kubota, M. C. Mendoza, S. P. Gygi, and J. Blenis
p90 Ribosomal S6 Kinase and p70 Ribosomal S6 Kinase Link Phosphorylation of the Eukaryotic Chaperonin Containing TCP-1 to Growth Factor, Insulin, and Nutrient Signaling
J. Biol. Chem.,
May 29, 2009;
284(22):
14939 - 14948.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. A. Cohn, Y. Kee, W. Haas, S. P. Gygi, and A. D. D'Andrea
UAF1 Is a Subunit of Multiple Deubiquitinating Enzyme Complexes
J. Biol. Chem.,
February 20, 2009;
284(8):
5343 - 5351.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Mann and N. L. Kelleher
Mass Spectrometry Special Feature: Precision proteomics: The case for high resolution and high mass accuracy
PNAS,
November 25, 2008;
105(47):
18132 - 18138.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Martins de Souza, B. M. Oliveira, E. Castro-Dias, F. V. Winck, R. S. O. Horiuchi, P. A. Baldasso, H. T. Caetano, N. K. D. Pires, S. Marangoni, and J. C. Novello
The untiring search for the most complete proteome representation: reviewing the methods
Brief Funct Genomic Proteomic,
July 1, 2008;
7(4):
312 - 321.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Brosch, S. Swamy, T. Hubbard, and J. Choudhary
Comparison of Mascot and X!Tandem Performance for Low and High Accuracy Mass Spectrometry and the Development of an Adjusted Mascot Threshold
Mol. Cell. Proteomics,
May 1, 2008;
7(5):
962 - 970.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Niu, X. Li, E. Job, C. Park, D. Moazed, S. P. Gygi, and N. M. Hollingsworth
Mek1 Kinase Is Regulated To Suppress Double-Strand Break Repair between Sister Chromatids during Budding Yeast Meiosis
Mol. Cell. Biol.,
August 1, 2007;
27(15):
5456 - 5467.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Zubarev and M. Mann
On the Proper Use of Mass Accuracy in Proteomics
Mol. Cell. Proteomics,
March 1, 2007;
6(3):
377 - 381.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Villen, S. A. Beausoleil, S. A. Gerber, and S. P. Gygi
Large-scale phosphorylation analysis of mouse liver
PNAS,
January 30, 2007;
104(5):
1488 - 1493.
[Abstract]
[Full Text]
[PDF]
|
 |
|
Copyright © 2006 by the American Society for Biochemistry and Molecular Biology.
|
Advertisement
Advertisement
|