Advertisement
MCP
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1074/mcp.M800108-MCP200 on July 24, 2008.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow All Versions of this Article:
M800108-MCP200v1
7/12/2410    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Glossary
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Szájli, E.
Right arrow Articles by Medzihradszky, K. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Szájli, E.
Right arrow Articles by Medzihradszky, K. F.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Molecular & Cellular Proteomics 7:2410-2418, 2008.
© 2008 by The American Society for Biochemistry and Molecular Biology, Inc.


Research

Investigating the Quantitative Nature of MALDI-TOF MS*,S

Emília Szájli{ddagger}, Tamás Fehér§ and Katalin F. Medzihradszky{ddagger},||

From the {ddagger} Proteomics Research Group and § Institute of Biochemistry, Biological Research Center, Hungarian Academy of Sciences, Temesvári körút 62, H-6726 Szeged, Hungary and Department of Pharmaceutical Chemistry, University of California, San Francisco, California 94143-0446

MALDI-TOF MS has been applied by several groups to relative quantitative measurements. At the same time, the non-quantitative character of this method has been widely reported. We conducted experiments to test the reliability of this technique for quantitation using the statistical method of inverse confidence limit calculation for the first time in this context. The relationship between relative intensities of known amounts of standard peptides and their concentration ratios was investigated. We found that the concentration ratios determined by relative intensity measurements were highly inaccurate and strongly influenced by the molecular milieu of the sample analyzed. Thus, we emphasize the necessity of using the sample itself for calibration. We also performed experiments using an isotope-labeled derivative of the analyte as an internal standard for calibration line generation. As expected, the use of such standard led to a dramatic increase in precision and a less pronounced improvement in accuracy. We recommend performing a similar statistical analysis as a demonstration of reliability for every system where MALDI-TOF MS is used for quantitative measurements.


|| To whom correspondence should be addressed. Tel.: 415-476-5160; Fax: 415-502-1655; E-mail: folkl{at}cgl.ucsf.edu


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 All ASBMB Journals   Journal of Biological Chemistry 
 Journal of Lipid Research   ASBMB Today 
Copyright © 2008 by the American Society for Biochemistry and Molecular Biology.
Advertisement
spacer
Advertisement
Advertisement