|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Molecular & Cellular Proteomics 5:1667-1680, 2006.
© 2006 by The American Society for Biochemistry and Molecular Biology, Inc.

,
,
,
,¶
From the
Department of Physiology (FYSP), Vrije Universiteit Brussel (VUB), 1090 Brussels, Belgium and
Division Studies, Epidemiology and Biostatistics, Department of Defense, 1120 Brussels, Belgium
| ABSTRACT |
|---|
|
|
|---|
In this context, because of its simplicity and highly reductionist in vitro approach, the phage display offers real advantages in dealing with pure membrane proteins if reconstituted in phospholipids. However identifying native interacting partners with the phage display still remained problematic. Over the years, the use of synthetic peptide libraries whether randomized (5), coupled to antibodies (6), coupled to portions of a receptor (7), or even affinity-selected for a known domain (8, 9) led in most cases to results that mimic but do not match the native peptide epitopes (5, 10, 11). Hence to identify such epitopes, the use of cDNA or genomic libraries would presumably be better. But it is fair to say that M13-derived phages never allowed a thorough screening of protein-protein interactions outside of the antigen-antibody realm (1015). Here using the lytic T7 phage system, we report the successful application of a selection strategy tailored for membrane proteins.
Our strategy combined (i) exploring the full set of the protein epitopes expressed in a human liver cell line, (ii) using the native fold of the membrane protein achieved by its successful functional incorporation into liposomes, and (iii) the high stability, small surface, and (mostly) controlled fluidics obtained by using a surface plasmon resonance (SPR)1 detector device. This represents a serious shift in the phage display and any affinity selection paradigm. First, it enabled us to work with very small reaction volumes (SPR measurement chamber). Having a small reacting surface (1 mm2) means fewer target sites, which is an advantage in terms of specificity. Usually the reacting surface is quite large as titer plates or target-coated beads are used. Second, the use of controlled fluidics enabled us to perform the selection in non-steady-state conditions. These are conditions where the mass transport, i.e. the availability of the potential ligands, is limited on the chip surface (16) thus presumably biasing the system toward high affinity multivalent ligands (17). In such a regime, where binding is influenced by transport, enhanced competition between ligand molecules is expected (18). Such conditions are generally avoided. The SPR device provided the added advantages of the stability and fractionation during the selection, both of which are not inherent to such a device. By fractionation under continuous flow of the output phages and iterations of the procedure, we demonstrated selection of phages and thus cellular epitopes with altered binding time constants.
With this method, we selected a set of 375 putative epitopes targeting the mitochondrial membrane protein voltage-dependent anion channel (VDAC). This protein is a key integration point in the control of metabolism and the apoptotic processes (1921), and it is involved in numerous protein-protein interactions including mitochondrial contact sites between both membranes (reviewed in this work; see references cited in Table IV). Independent functional testing narrowed these epitopes to a subset of 75 functional sequences among which 55 concern novel proteins interacting with the target. The validity of such an approach is further evidenced by the fact that we were able to confirm at least 40% of the independently known interactions for our chosen target protein. This compares more than favorably with competing approaches with confirmation rates of already known interactions at or below 10%.
|
| EXPERIMENTAL PROCEDURES |
|---|
|
|
|---|
-phosphatidylcholine Type II-S from soybean (Sigma) supplemented with 20% pure cholesterol (Sigma). Running buffer HBS-N (0.15 M NaCl, 10 mM HEPES, pH 7.4) was filtered and degassed (Biacore®). Crystal grade cytochrome c oxidase was kindly provided by Dr. Verkhovsky, Helsinki, Finland.
Liposome Preparation
Phospholipids (1.52 mg) with 20% cholesterol (0.3 mg) were dissolved in 1 ml of hexane in a 10-ml round bottom flask. A thin lipid film was deposited by evaporation of hexane under a filtered N2 stream (0.22-µm filter). One milliliter of experimental buffer (1 M KCl, 5 mM CaCl2, 10 mM HEPES, pH 7.2, filtered through 0.22-µm filters) was added, and multilamellar vesicles were formed by extensive vortexing. The lipid suspension was then submitted to four freeze-thaw cycles and to a 10-s sonication period to yield large unilamellar vesicles (LUVs). Finally the size of these vesicles was homogenized by pushing the suspension 2530 times through a 100-nm polycarbonate filter in a mini extruder (Avanti® Polar Lipids, Inc.).
VDAC Liposomes
VDAC liposomes were obtained by diluting (1:3, v/v) the previous liposome (LUV) suspension with 50% experimental buffer (as above) and by adding twice separately 50 µl of a purified VDAC-containing solution (1 mg/ml VDAC in 5 mM Tris, pH 7, 0.5 mM EDTA, 2.5 mM KH2PO4, 25 mM KCl, 1% Triton) to 400 µl of liposomes, waiting each time 10 min for VDAC to insert. The VDAC proteoliposomes were then diluted (1:3, v/v) in an appropriate buffer (30 mM KCl, 10 mM HEPES, pH 7.4, filtered through 0.22-µm filters) to obtain a final VDAC LUV suspension with a very low final Triton concentration (0.05%), a physiological osmolarity (300 mosM), and a lipid concentration of 7.6 µg/ml. Blank liposomes (without any protein) were made and diluted in the same fashion.
Liposome Immobilization on an L1 Sensor Chip
Vesicles were captured on the L1 sensor chip as described previously (24). After a short time the surface of an L1 sensor chip was cleaned by a 2-min injection of 20 mM CHAPS at a flow rate of 20 µl/min followed by the "extra clean" rinsing routine. HBS-N was used as running buffer after filtration and degassing. Liposomes (80 µl, 1 mM lipids) were then immediately injected at a flow rate of 2 µl/min and captured. This fixed lipid layer was then washed at a flow rate of 100 µl/min with sodium hydroxide (10 mM, 50 µl). In the case of VDAC liposomes, 120 µl of proteoliposome solution (1 mM phospholipids, flow rate identical) were used. A 12-h-long control period (running buffer at 5 µl/min) was needed to ascertain the stability of the chip surface. For the proteoliposomes, the SPR signal values showed a relatively important drift after 2 h of stabilization (around 3 resonance units (RU)/min for typical experiments); this drift reached its lowest possible values after waiting overnight and fell at the reported intrinsic drift range of the device (<0.3 RU/min) (technical handbook). For the blank liposomes, such low values were already reached after 2 h. The degree of coverage of the surface of the chip was determined by the ratios of the background reading signals (in relative RU) in the presence or absence of liposomes. The uncovered chip surface was then blocked with BSA (0.1 mg/ml, injection of 25 µl at 5 µl/min) (25).
Biopanning of the Phage Library against VDAC Liposomes
The T7-SelectTM Liver library (Novagen, Madison, WI) was used. This cDNA library expresses its inserts fused to the C terminus of the T7 gene10B major capsid protein with an average of 10 copies displayed per virion, and inserts range from 300 to 3000 bp. The biopanning rounds were performed in a Biacore 2000 instrument (Biacore AB, Uppsala, Sweden) using an L1 sensor chip and HBS-N (above) as running buffer.
Phage Selection
To select for phages that bind to VDAC, the initial library was amplified and injected at very low flow rate (1 µl/min) over a chip covered with VDAC liposomes (
5000-RU level). Such a low flow rate allows a better competition between the viral particles for the binding sites. To filter out the phages bearing plain lipophilic epitopes or epitopes targeted to BSA, i.e. to increase the specific signal to noise ratio, the phage solution is first flushed at the same flow rate over three flow cells covered with blank liposomes (covered at
7000-RU level) and blocked with BSA before being allowed to reach the fourth flow cell with proteoliposomes. A titer of 109 phages/100 µl was used to cover the whole range of the library sequence space (107 variants/ml, manufacturers manual and our own control). Such panning rounds were repeated three times.
Phage Collection
Following the competition and binding phase, the reaction chamber was briefly washed with buffer (5 min at 1 µl/min) to remove any unbound or poorly bound material. To recover VDAC-binding phages based on different release rates, fraction collection was performed from flow cell 4. An amount of buffer was injected at 1 µl/min and recovered in full after 10 min for the first eluted fraction, after 30 min for the second eluted fraction, and after 40 min each for the third and fourth fractions. This was consecutively performed thus yielding four phage fractions. As a control for the selective enrichment the same procedure was used over flow cell 3 (liposome only-binding phages). As prior to the next panning round the chip surface had to be regenerated, the phages with extremely low dissociation rate constants (near "irreversible" binders) were collected during a regeneration procedure. To that effect the sensor chip was first washed thoroughly by injection of buffer at high flow rate (90 µl at 30 µl/min) followed by an injection of 1% SDS (6 µl at 2 µl/min) to remove phages and liposomes from the sensor surface. T7 phages are resistant to a brief exposure (35 min) to 1% SDS and if directly diluted after recovery (SDS samples are brought to a volume of 30 µl with HBS-N) can reliably be titrated and propagated.
Phage Amplification and Titration
Phage titers were determined by infection of 250 µl of BLT5615 cells, harvested in the presence of carbenicillin (50 µg/ml), with 100 µl of a 10-fold dilution of the eluted phages. The cell-phage samples were added to 3 ml of H-top agar containing 4 mM IPTG and plated on LB agar supplemented with carbenicillin. IPTG is required to induce the production of the 10A capsid protein of the T7 phages. The plates were left overnight at room temperature; the number of plaque-forming units (pfu) was counted for all samples.
To amplify the phages in between each selection round, 10 ml of BLT5615 cells (harvested at log phase in the presence of carbenicillin and 1 mM IPTG) were infected with 20 µl of phage eluate. Incubation for a maximum of 1.5 h at 37 °C in a sterile chamber caused complete lyses of the cells. Cell debris was removed by centrifugation for 10 min at 8000 x g, and 15% chloroform was added to the phage-containing supernatant to clear the sample from unprecipitated debris. This step was found to be essential to decrease microfluidics (chip) and macrofluidics (catheters) problems within the Biacore machine. The catheters of the machine were changed in between rounds of testing. The phage samples were further purified by PEG precipitation (phages: PEG 6000, 50% solution, 1:6, v/v) and finally dissolved in HBS-N. Phage titers following amplification were determined as described above.
Affinity Tests of the Selected Phage Populations
To evaluate the binding of phage populations selected from a surface-displayed library, affinity tests were performed within the SPR device (26). The L1 sensor chip was covered either with VDAC liposomes or liposomes and blocked (see above). Coverage of the chip surface was kept high, typically around 7000 RU for VDAC liposomes and 8000 RU for liposomes. Amplified phage populations at a concentration of 3.3 x 1010 pfu/ml were injected separately over the two surfaces at a high flow rate (30 µl/min) for 2 min after which dissociation curves were followed for 10 min. Prior to each injection of phages, a buffer-only control run was performed.
Single Clone Amplification
A portion of the top agarose of individual plaques was scraped up and used to infect 10 ml of BLT5615 cells as described above.
PCR Amplification of cDNA Inserts and Sequencing
The T7 library protocol (Novagen) was strictly followed. Finally the samples were purified (Qiaquick purification kit), and purity was controlled by electrophoresis on a 1% agarose gel. The PCR amplified DNA was submitted for DNA sequencing with the T7Forward primer.
Epitope Identification
Using the BLAST Network Client "blastcl3" program, all DNA inserts of the 375 clones were compared with the non-redundant (nr) nucleotide sequence databases, i.e. all of GenBankTM + EMBL + DDBJ sequences. For the 547 non-redundant identifiers in the database (894 with redundancy), the homologies were mostly greater than 90% but at least 75% and a minimum length of 30 bp (with the exception of 16 hits around 20 bp). The difference between the numbers of identifiers and sequences is presumably due to similar DNA sequences present in different genes, i.e. encoding similar domains in markedly different proteins. This was specifically controlled for four randomly chosen clones (data not shown). 481 proteins were obtained by subtracting irrelevant data (pseudogenes, non-protein DNA, RNA, and clusters) from the 547 identifiers.
Cytochrome c Oxidase Assay
Functional effects of VDAC on cytochrome c oxidase (COX) were assayed by following the oxidation of reduced cytochrome c at 550 nm by COX according to Roman et al. (27). Spontaneous oxidation of cytochrome c was controlled and found to be less than 1% in the absence of the enzyme.
VDAC Permeability Assay
VDAC liposomes (LUVs) were prepared as described above except for an additional dilution step (1:2, v/v) in 0.75 M KCl and stabilized on ice for 30 min. Fixed volumes of phages (2 x 1092 x 1010 phage particles, controlled by titration) were added to 200 µl of proteoliposomes solution, the mixture was stabilized for 10 min, and 10 µl of a 200 mM stock of PEG 800 (final concentration, 10 mM) was added right before reading. Volume changes were recorded as variations in light scattering with a Bio-Rad microplate reader at 400 nm. Slopes during the reswelling phase of the experiments were computed by linear fits.
| RESULTS |
|---|
|
|
|---|
Screening cDNA Libraries
The biopanning selection was performed within the biosensor device (Fig. 1a, black arrows). This selection phase comprised three steps. In the first step, the naïve phage library is first amplified and injected at the lowest possible flow rate into the machine, and the phages are forced to pass sequentially over the three blank flow cells before competing for target binding. Such a low flow rate would theoretically allow a better competition between the viral particles for the target binding sites. Forcing the phages on the first three flow cells allowed us to filter out the phages bearing plain lipophilic epitopes or epitopes targeted to the blocking agent (BSA). In an ensuing step (Fig. 1a, red arrows), the phages that bound to both proteoliposomes or blank liposomes would be eluted and fractionated by perfusing a mild running buffer into the respective chambers. This would collect the positive binders based on their release rates from the bait protein. At this stage, a third step (not shown on the figure) was to disrupt the chip surface with detergent. This enabled us to collect undissociated phage particles in a last fraction termed the regenerate. All these fractions were then analyzed for bulk affinity in separate sets of experiments (Fig. 1b). An example of such affinity measurement is given in Fig. 1c. For each fraction, specific versus aspecific bulk binding varies. In our example, fraction 2 yielded the best signal. This does not imply that this fraction contains the best ligands but that this fraction contains more phages with fairly good binding epitopes. Based on the need (high or low affinity), each of these fractions can be used as the seeding stock for the next phage generation, enabling a wide range of different biopanning strategies (see Fig. 1d).
|
|
|
|
|
|
In addition to such a basic comparison, a more systematic screening of the eventual functional effects of the selected epitopes was warranted to further validate a portion of our dataset and thus our method. This was performed based on the ion channel function of the target molecule rather than on plain binding. VDAC function can be assayed by measuring volume changes in proteoliposomes. This is easily arrayed in microwell titer plates. In Fig. 4, following appropriate functional and permeability controls (Fig. 4, a and b), several permeability curves obtained with those clones are shown for illustrative purposes. The slopes during the reswelling phase are proportional to the channel permeability. Based on this assay and by comparison with the response obtained with the naïve library (used as negative control; slope values, 6 ± 1), we could classify our epitope sequences as either neutral (slope values, 58), channel openers (slope values, >10), or channel inhibitors (slope values, <3). We chose such marked cutoffs to focus on reliable major effects. Of all our 375 tested epitopes, 116 were neutral, 24 were openers, and 51 were inhibitors. Of major interest is that five of the latter clones either fully or near fully blocked the channel. The possibility to record a full block is also additional evidence that our proteoliposomes were not leaky. The remainder (184 clones) gave unreliable results. As some of the clones bore fragments from the same protein, we identified a total of 55 different epitopes able to functionally interact with our target in a permeability assay (listed in Supplemental Results).
|
| DISCUSSION |
|---|
|
|
|---|
The control of the fluidics was obtained by SPR. As far as SPR is concerned, some reports exist of selection against soluble proteins or for antibody engineering (32); panning was performed inside the device but without reamplification between rounds. So far SPR machines have mostly been used for evaluating panning results and finding which single clones to sequence. By eluting and fractionating the bound phage populations, we could perform various selection strategies based on the relative affinities of the phage for the target protein. At first glance, this could also be achieved from panning performed in test tube, but there is still a major difference. In the test tube the binding molecules are allowed to reach steady-state conditions, whereas by design, in our experiment this will never be the case because of the presence of a competition between the diffusion and the perfusion processes during the selection. Indeed the real advantages of the SPR device for us lay with its microfluidics: the epitope-bearing viruses were very slowly perfused (1 µl/min) in the small volume and minute binding surface of a reaction chamber (0.06 µl, 1 mm2) for 100 min. This unusual geometry has various useful consequences for ligand selection. First, working with fewer binding sites theoretically enhances selectivity. These target sites could even be fewer due to the probable presence of incorrectly reconstituted protein. Even with such a caveat, it remains that ligands with better selectivity would be selected, albeit against irrelevant protein epitopes. Then kinetic analysis requires working in conditions where the binding molecules are not mass-limited but diffusion-limited. In such conditions the collision rate is maximal around 109 M1 s1; the effective collision rate yielding actual binding is smaller. Alternatively if one is not interested in kinetic parameters but in binding, then limitations in analyte/substrate availability may become useful. It is known that, at low flow rates (5 µl/min), mass transport of the perfused molecules becomes limiting in the SPR device that we used (16). Because we used even slower flow rates (1 µl/min) and because our viral particles have a diffusion coefficient that is 2 orders of magnitude lower than those of proteins (D = 0.6 x 107 cm2/s for the T7 icosahedral particles (33)), it is quite certain that we are in such a mass-limited regime in the panning chamber during the selection process. It has been predicted that in such conditions, i.e. binding influenced by transport and heterogeneity in the free analyte, the binding will likely be due to the population of molecules having the higher association rate constants and/or lower diffusion coefficients (17). In short we are working in conditions mostly avoided when using SPR but in which likely better epitopes against the target ought to be selected. In those limiting conditions, the receptors (our target VDAC) would compete for binding during the association phase, and epitope rebinding is likely to occur during the dissociation phase (18). Because a longer time is needed to reach a given binding level, multivalent binders, needing more time to bind, would be favored. This should presumably work well with the T7 phages (low copy multivalent epitope display). For these reasons, performing biopanning rounds on bead-fixed proteoliposomes (e.g. see Ref. 34) cannot be considered a comparable method.
No golden standard exists to massively screen for ligands/epitopes. Numerous methods have been developed and used, and each seemingly imposes its own technical biases upon the selection process (for a review, see Ref. 2). No method exists to identify and validate putative ligands at the same time. A more detailed and critical review of the relevant literature (see Supplemental Discussion) evidences that no large scale method can be considered complete, that each generates more than its fair share of false positive as well as negative results, that combining independent methods will offer the most promising and accurate results, and that, regardless of what some wording may suggest, reliably screening for epitopes against membrane proteins still remains out of reach for nearly all of the newly developed techniques. In this context, novel adaptations of the yeast two-hybrid (Y2H) systems and phage display would be of value. The former is usually not membrane protein-friendly because among the false negative results from the Y2H systems 60% are membrane protein.2 Recently developed membrane-based Y2H methods have not been thoroughly tested yet, but obtaining in such systems a huge variation of epitopes to screen from is quite labor-intensive. Alternatively the phage display, although easy to perform and cost-effective, remains a prokaryotic system that is likely to miss interactions that are carried by the post-translational modifications of the protein epitopes. Although some eukaryotic cell display methods have been set up, the epitopes selectively targeted against membrane proteins remain once again mostly out of reach (35). The phage display, because it is an in vitro system, thus remains a powerful method especially when dealing with reconstituted membrane proteins and smaller epitopes (36).
In addition to being biased toward putatively better ligands and designed for epitopes against membrane proteins, our own adaptation of this method offers several other advantages. Because of the fractionation possibilities, the same set of epitopes can undergo various selection strategies depending on the needs of the experimentation. We did not "elute" the very strongly attached viral particles by breaking their binding with an acid of a detergent washout; we let them elute under running buffer conditions. We found that, based on the stability of the association, we could obtain phage fractions with different bulk affinities and different enrichment in terms of cellular epitopes (like the enrichment in mitochondrial proteins seen in fraction 3). Performing the quality control steps within the machine using an identical setup is also advantageous. In some phage display setups, panning and testing happen in different conditions; this is not experimentally optimal. The use of machines allows the method to be scaled up and automated with the appropriate design modifications of the equipment.
In our case, about 375 insert sequences allowed us to identify highly similar (>90%) portions of genes from 580 different proteins. Although identifying related domains in different proteins yields interesting functional clues, it does not solve the relevance of all obtained epitopes. It trims down the genome to a subset of possible candidates. To further sort out the most relevant clones from a putative subset, one has to use another independent method to control each selected clone. The most obvious strategy is direct binding (in the form of ELISA plates, of SPR binding measurement, etc.). But binding in vitro does not demonstrate cellular function. Functional assays are thus better as long as the function of the target protein is known. In our case this was realized under the form of a VDAC proteoliposome permeability test. This yielded a putatively more relevant subset of epitopes on which to focus. This subset consists of the clones displaying a relative permeability range at least double or less than half the value obtained with the naïve library. According to these criteria, we narrowed the dataset to 55 functional epitopes of 375 clones, likely trimming down the occurrences of false positives. To further validate these functional epitopes, more independent assays now ought be performed. Depending on the function of each of these putative VDAC binders, enzymatic, colorimetric, and/or other function-specific assays could be developed in addition to direct binding verification and permeability.
Our system also has its own built-in biases. Obviously hydrophobic epitopes could have been favored by our setup. The fact that we cleared out such clones on the first three flow cells decreased this possibility. A possible misfolding of VDAC into proteoliposomes could allow the selection of irrelevant phages. However, the careful VDAC reconstruction protocol minimizes this possibility. Another (uncontrollable) bias of our system is that the phage needs to replicate itself in between panning rounds. It is possible that an effective selective pressure geared toward binding may render the bearer of such epitope less able to compete during our reamplification rounds. This would lead to the loss of potentially relevant epitopes.
Another way to gauge our methodology would be to critically review its outputs with what is already known for VDAC-interacting proteins. We found at least nine of 24 reported protein-protein interactions, and in five more cases we hit on related proteins. Although the chances of this resulting by sheer chance are trivial and support our approaches, we still missed some expected and well documented interactions like the hexokinase or the TOM20 protein. According to our method (including a 5-min washout), we are likely to lose rapidly reversible ligands. Such would be the case of the TOM20 protein whose interaction is reported as being highly labile (37). Furthermore the structure of our target protein functionally embedded into phospholipid membranes is totally different from the looser structure recognized by the import machinery (37, 38). Although also readily reversible and hence labile, the interactions between VDAC and hexokinases or glycerol kinases may also have been missed due to our choice of protein isoform; the correct ligand remains the human VDAC1 (39). Moreover VDAC-bound hexokinases are not expressed in the liver. As for the mitochondrial creatine kinase, its association with VDAC is calcium-dependent (40); as our selection buffer contained no Ca2+, it is an expected miss. Of all the apoptosis-related proteins presumably interacting with our target (4144), we found Bcl-2 and three other proteins not yet reported but not Bax, Bak, Bid, Bim, or Bcl-xL. We did not expect Bak. Bak is reported to bind HVDAC2 not HVDAC1, our target ortholog (19). Recent data suggest that Bcl-xL needs to be inserted into the phospholipid membrane to bind and affect VDAC (42); if so we could not have found this protein either. Thus the situation is likely very complex, and it is also worth mentioning that there still is a debate about the precise nature of the apoptotic proteins interacting with our target. Among other possible false negative results, we should mention that some relevant binders are likely lost due to the experimental processing; there could be sequencing errors/problems or epitope sequences for which there are no matches in the database or that match still unidentified DNA. More importantly, we should not forget to include epitopes that will be underrepresented or absent from the initial library. Having used a liver cell library from normal human could explain the poor representation of some proteins and the absence of the mitochondrial benzodiazepine receptor (mPBR) and of the hexokinase that are not expressed in normal hepatocytes (45). Starting with another cell type, a cancer cell line, or other disease-related libraries may have yielded other results. The fact that we used a cDNA instead of a genomic library may also have biased our results toward heavily translated genes with more stable RNA. Thus, we could convincingly argue that we found most proteins that we could reasonably expect to find. This amounts to at least 38% of the known interactions and compares more than favorably with other reports of 13% of known interactions found (46) or even less than 5% (4749). This useful approach is generally applicable for any protein and could be automated and scaled up even without the use of a SPR device.
Other mitochondrial proteins from our potential VDAC binders list demand a further analysis, but time limited the development and/or adaptation of additional assays. As for all high throughput methods, an ensuing validation of the ligands must be performed by biochemical methods. It is evident that an ensuing step is required to measure the accuracy of each interaction. Although some of the identified potential VDAC partners could readily tempt us to functional speculations, independent biochemical verification is very much required.
Another way to select a subset of the putative binders for further validation is to focus on the most functionally relevant clones. We performed a rapid functional screening assay based on the channel function of VDAC. This yielded a first subset of 75 functional clones, from which, 32 could be reliably identified with a protein in the database. Some of these clones were VDAC openers and some inhibited the VDAC permeability. A more accurate assay should now be performed to validate these potential VDAC regulating protein-epitopes.
| FOOTNOTES |
|---|
Published, MCP Papers in Press, May 29, 2006, DOI 10.1074/mcp.T600009-MCP200
1 The abbreviations used are: SPR, surface plasmon resonance; VDAC, voltage-dependent anion channel; LUV, large unilamellar vesicle; RU, response unit(s); IPTG, isopropyl 1-thio-ß-D-galactopyranoside; pfu, plaque-forming units; PEG, polyethylene glycol; COX, cytochrome c oxidase; Y2H, yeast two-hybrid. ![]()
2 Myriad Genetics Corp., I. Fraser, personal communication. ![]()
* The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact. ![]()
S The on-line version of this article (available at http://www.mcponline.org) contains supplemental material. ![]()
¶ To whom correspondence should be addressed: Vrije Universiteit Brussel (VUB), Dept. of Physiology (FYSP), Faculty of Medicine and Pharmacy, Laarbeeklaan 103, 1090 Brussels, Belgium. Tel.: 32-2-477-4434; Fax: 32-2-477-4568; E-mail: martin.zizi{at}vub.ac.be
| REFERENCES |
|---|
|
|
|---|