|
Advertisement | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Molecular & Cellular Proteomics 6:2139-2149, 2007.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ABSTRACT |
|---|
|
|
|---|
S. aureus superantigenic toxins (enterotoxins and toxic shock syndrome toxin-1 [TSST-1]) are virulence factors responsible for severe diseases in humans among which the highly lethal staphylococcal toxic shock syndrome (14, 15). Staphylococcal toxic shock syndrome is related to the ability of enterotoxins and TSST-1 to polyclonally and extensively activate T cells at picomolar concentrations, a property referred to as superantigenicity. Besides their superantigenic activity, staphylococcal enterotoxins also display specific emetic properties and constitute a major cause of food poisoning (15). For all these reasons, staphylococcal enterotoxins constitute a significant threat as biological weapons. The Center for Disease Control has registered the staphylococcal enterotoxin B (SEB) as a potential warfare contaminant of food and water supplies. To date, 19 staphylococcal enterotoxins have been identified (variant forms excluded) and are associated with different clinical profiles (15–17). Extensive sequence and structure similarities between staphylococcal superantigenic toxins have so far precluded the development of specific and comprehensive immunological tools. As a result, no diagnostic test is presently available for the staphylococcal toxic shock syndrome. Furthermore, no assay is referenced for the identification and quantification of these toxins in accidentally or deliberately contaminated food or water supplies. In this context, MS, which circumvents the need for antibodies, offers great potential for staphylococcal superantigenic toxin-specific detection and quantification.
In this work, we present an MS-based methodology to detect and quantify the staphylococcal superantigenic toxins SEA and TSST-1, which are the most frequently involved toxins in staphylococcal toxic shock syndrome (15, 16). Drinking water and human urine were selected as preferred matrices for warfare agent surveillance and clinical diagnosis. Comparisons with the current state-of-the-art methodologies demonstrate the great potential of isotope-labeled full-length proteins as standards for MS-based absolute quantification.
| EXPERIMENTAL PROCEDURES |
|---|
|
|
|---|
Synthesis, Purification, and Quantification of the Isotope-labeled QconCAT Concatemer—
The QconCAT protein was designed as shown in Fig. 1. Briefly, tryptic peptides from eight staphylococcal superantigenic toxins (SEA, SEB, TSST-1, staphylococcal enterotoxin G, staphylococcal enterotoxin I, staphylococcal enterotoxin M, staphylococcal enterotoxin N, and staphylococcal enterotoxin O) were selected according to their uniqueness of sequence among the staphylococcal superantigens and their detectability in nano-LC-MS analysis. These peptide sequences were concatened into an artificial QconCAT protein and retro-translated to design the corresponding artificial QconCAT gene (see references 9 and 11 for more details). The QconCAT gene was synthesized from 53 5' phosphorylated oligonucleotides (Sigma-Genosys) covering the forward and reverse strands (Supplemental Fig. 1). The synthetic QconCAT gene was assembled by ligase chain reaction with TaqDNA ligase (New England Biolabs, Frankfurt, Germany) and amplified with the Expand High Fidelity polymerase (Roche, Meylan, France) using the primers mentioned in Supplemental Table I. The amplified QconCAT gene was purified, digested with NcoI (Roche) and SmaI (New England Biolabs), and inserted into the pIVEX 2.3d vector (Roche) providing a C-terminal hexahistidine purification tag. Ligation was achieved using the Rapid DNA Ligation Kit (Roche). The resulting plasmid was cloned into strain XL1-Blue (Stratagene, Amsterdam, Nederlands) and was purified using QIAprep Spin Miniprep Kit (Qiagen, Courtaboeuf, France). Finally, we checked the QconCAT construct sequence before its use for recombinant protein synthesis (Genome Express, Meylan, France). QconCAT protein production was performed in vitro using the RTS 500 ProteoMaster Escherichia coli HY Kit (Roche) according to the manufacturer's instructions with the following modifications: we used the RTS Amino Acid Sampler Kit (Roche) instead of the amino acid mix provided, and we replaced L-lysine and L-arginine by isotope-labeled [13C6, 15N2] L-lysine and [13C6, 15N4] L-arginine (Cambridge Isotope Laboratories, Andover, MA). The isotope enrichment of [13C6, 15N2] L-lysine and [13C6, 15N4] L-arginine was 98% 13C and 98% 15N. QconCAT protein was efficiently produced in a precipitated form and was solubilized in guanidine 6N. QconCAT purification was performed on a nickel affinity column (Ni Sepharose 6 Fast Flow, Amersham Biosciences, Freiburg, Germany) using a 20 mM-250 mM imidazole gradient in guanidine 6N. After purification, QconCAT was sequentially dialyzed against pure water and 1% SDS, Tris HCl 50 mM, pH 7.5. QconCAT quantification was performed by AAA on a Biochrom 30 Amino Acid Analyser (Biochrom, Cambridge, UK). QconCAT primary structure and isotope labeling was further assessed by nano-LC-MS/MS and nano-LC-MS analysis (Supplemental Fig. 2).
|
SDS-PAGE Quality Control—
Home-produced PSAQ proteins and purchased SEA and TSST-1 were all checked for purity on SDS-PAGE using both Imperial Protein Stain and SYPRO Ruby staining (Bio-Rad, Marnes-la-Coquette, France). The quantities of commercial toxins were too limited for AAA analysis, and commercial TSST-1 toxin displayed a contamination by a higher molecular weight protein precluding an accurate AAA quantification. Thus, commercial toxin concentrations were evaluated by comparison with our AAA calibrated PSAQ standards on SDS-PAGE using SYPRO Ruby staining (19). SYPRO Ruby fluorescence was scanned (Laser 532 nm, filter 610BP30) on a Typhoon 9400 (Amersham Biosciences). When compared with our AAA calibrated PSAQ standards, the announced concentrations of commercial SEA and TSST toxins turned out to be overestimated (Supplemental Fig. 3). Therefore, the commercial toxin concentrations were corrected, and the corrected values were used in all subsequent calculations.
Water Sample Preparation and Trypsin Digestion for MS Analyses—
Drinking water samples were contaminated with five different quantities of SEA and TSST-1 commercial toxins. Each sample was divided into nine aliquots of 120 µl each. Three aliquots (analytical replicates) of each sample were spiked with either QconCAT or PSAQ toxins standards in defined quantities. Trypsin digestion was performed in solution using sequencing grade modified trypsin (Promega, Madison, WI) at a 1:2 protease to toxins ratio in 25 mM NH4HCO3 overnight at 37 °C. Samples were dried by vacuum centrifugation and resolubilized in 5% ACN, 0.2% formic acid. Before nano-LC-MS analysis, AQUA peptides were added in defined quantities into the aliquots that contained neither QconCAT nor PSAQ standards.
Urine Sample Preparation and Trypsin Digestion for MS Analyses—
Urine from a 30-year-old healthy woman was collected and contaminated with four different quantities of SEA and TSST-1 commercial toxins. Each sample was divided into nine aliquots of 100 µl each. Three aliquots (analytical replicates) of each sample were contaminated with PSAQ toxin standards in defined amounts. Each 100 µl aliquot was adsorbed on 5 µl of Strataclean resin (Stratagene) according to the manufacturer's instructions. Following elimination of supernatant, proteins adsorbed onto the resin were directly eluted in 10 µl of a depolymerization buffer containing 2% SDS and 5% β-mercaptoethanol. At this stage, QconCAT standard was added in controlled quantities into half of the samples devoid of PSAQ standards. After a thermal denaturation step at 95 °C for 5 min, samples were loaded on precast Novex NuPAGE Bis–Tris gels (4–12% acrylamide gradient) purchased from Invitrogen (Cergy Pontoise, France). Gels were run for 30 min under 200 V, fixed for 30 min in 30% ethanol-7.5% acetic acid, and stained with Biosafe Coomassie blue (Bio-Rad). In the 25 kDa region of the gel encompassing toxins and QconCAT, protein bands were excised and were destained by repeated cycles of incubation in 25 mM NH4HCO3 for 15 min and then with 50% (v/v) ACN in the same buffer (25 mM NH4HCO3) for 15 min. After drying by vacuum centrifugation, the gel pieces were incubated with an oxidizing solution (7% H2O2) for 15 min (20). Gel pieces were then washed in HPLC grade water (Sigma-Aldrich) for 15 min before being dehydrated with 100% ACN. In-gel digestion was performed using 1:2 trypsin to protein ratio (sequencing grade modified trypsin, Promega) in 25 mM NH4HCO3 overnight at 37 °C. Peptides were extracted from the gel using passive diffusion in the following solutions: 50% ACN, then 5% formic acid, and finally 100% ACN. The extracts were dried by vacuum centrifugation, and peptides were resolubilized in 5% ACN, 0.2% formic acid. Before nano-LC-MS analysis, controlled amounts of AQUA peptides were added to the samples that had not been spiked with PSAQ or QconCAT standards.
Nano-LC-MS and Nano-LC-MS/MS Analyses—
MS analyses were performed on a nano-LC system coupled to a QTOF Ultima mass spectrometer (Waters, Milford, MA). Briefly, peptide digests were first concentrated on a 300 µm x 5 mm PepMap C18 precolumn (LC-Packings-Dionex, Sunnyvale, CA). Peptide digests were then passed onto a C18 column (75 µm x 150 mm) (LC-Packings-Dionex) and eluted with a gradient from 10% ACN, 0.1% formic acid to 80% ACN, 0.08% formic acid (run duration 60 min, flow rate 200 nl/min). The mass spectrometer was operated in the positive ion electrospray ionization mode with a resolution of 9000 to 11,000 full-width half-maximum. Data-dependent analysis was used for MS/MS (three most abundant ions in each cycle): 1 s MS (m/z 400–1600) and maximum 4 s MS/MS (m/z 50–2000, continuum mode) with 2 min dynamic exclusion. MS/MS raw data were processed using MassLynx 4.0 software (smooth 3/2 Savitzky Golay) (Waters). Peptide identifications from the resulting MS/MS dataset were achieved using an in-house MASCOT server (version 2.0) (Matrix Sciences, London). Full specifications of search parameters are presented in supplemental data files. Quantification was done manually from nano-LC-MS data after integration of peaks for unlabeled/labeled peptide pairs on reconstituted chromatograms obtained by extraction of a specific mass (±0.1 Da) with MassLynx 4.0 software. The minimum signal to noise ratio considered for quantitation was 15:1.
| RESULTS |
|---|
|
|
|---|
|
m = 7 Da ([13C6, 15N] L-leucine peptides) were observed in the MS survey. Each of these peak doublets was integrated to determine the total ion signal of the natural peptide (mass m) and its corresponding labeled AQUA standard (mass m +
m). The ratio of these signals allowed a direct calculation of the estimated natural toxin amount which was plotted against the added amount (Fig. 2). Ideally, 100% recovery should have been observed. The SEA and TSST-1 titration curves obtained were linear for added amounts of toxins ranging from 50 to 750 pg. Deviation from linearity above these values resulted from ion signal saturation. The measurements of accuracy and precision were evaluated through the slope values of the titration curves and the standard mean errors (S.E.) values of the data, respectively. AQUA peptide standardization is a highly precise quantification strategy (Fig. 2). However, regarding accuracy, an important discrepancy between the two AQUA peptides targeting SEA was observed (slope value = 1.37 for YNLYNSDVFDGK peptide and slope value = 0.44 for NVTVQELDQAR peptide) (Fig. 2A). Three potentials biases may account for such results: 1) AQUA peptides were quantified by the provider using AAA, obtained lyophilized, and re-solubilized according to the provider's own guidelines. Nevertheless, quantitative re-solubilization should not be taken for granted, and a subsequent evaluation of the re-solubilized peptide by AAA would require much more material than provided. 2) AQUA standards have to be highly diluted prior to their addition into the samples. Depending on their physicochemical properties, dilution of pure peptides can lead to important losses of peptide by adsorption onto vials. 3) Standardization with AQUA peptides does not take into account the yield of the protease digestion step. This step introduces variability due to the intrinsic susceptibility of each protein or protein domain to proteolysis. In addition, variability between samples can also originate from the digestion conditions (e.g. composition of the sample buffer, amount of trypsin, temperature during incubation). Standard peptide adsorption onto vials or incomplete solubilization both lead to an overestimation of the true standard concentration and consequently of the targeted protein. Accordingly, the 37% overestimation of SEA abundance given by the AQUA peptide YNLYNSDVFDGK (slope value = 1.37) likely resulted from incomplete re-solubilization and/or partial adsorption of this standard peptide onto vials. Conversely, the peptides NVTVQELDQAR and LPTPIELPLK may not have been efficiently generated by trypsin digestion and therefore led to an important underestimation of SEA and TSST-1 abundances (slope values = 0.44 and 0.54, respectively). This stresses a major limitation of the AQUA peptide strategy: it does not take into account the actual digestion yield of the different peptides from the native protein. Actually, this drawback is especially problematic for proteins such as staphylococcal superantigenic toxins, which are known to be poorly protease sensitive (15).
|
In agreement with previous reports (21), the cell-free expression of QconCAT in the presence of [13C6, 15N2]-lysine and [13C6, 15N4]-arginine yielded a high rate of isotope-label incorporation. A nano-LC-MS analysis of the pure isotope-labeled QconCAT indicated an isotopic purity greater than 98% (Supplemental Fig. 2). Moreover, [13C6, 15N2]-lysine and [13C6, 15N4]-arginine-labeling leads to constant mass increments of arginyl and lysyl peptides after trypsin cleavage, which greatly simplifies the processing of LC-MS data required for quantification. Therefore, for each of the marker peptides selected (Table I), peak doublets separated by a mass of 8 Da ([13C6, 15N2]-lysine-labeled peptides) or 10 Da [13C6, 15N4]-arginine-labeled peptides) were investigated. The ratios of unlabeled over labeled peptide signals allowed a direct calculation of the estimated natural toxin amount that was plotted against the added amount (Figs. 3 and 4).
|
|
Therefore, in subsequent experiments aimed at quantifying SEA and TSST-1 in drinking water, the QconCAT standard was codigested with the artificially contaminated samples. Although the six marker peptides could be observed in nano-LC-MS analysis, they exhibited quite different MS detectability. To enhance quantification sensitivity, we focused on the four marker peptides that gave the best nano-LC-MS signals (NVTVQELDLQAR, QNTVPLETVK, YNLYNSDVFDGK for SEA, and LPTPIELPLK for TSST-1). In contrast with SEA titrations obtained with the two AQUA peptides YNLYNSDVFDGK and NVTVQELDLQAR, the three QconCAT-generated SEA peptide standards displayed only limited variance (compare Fig. 2A and Fig. 4A). This higher consistency is attributed to the equi-stoichiometric representation of peptide standards in the QconCAT construct. However, QconCAT quantifications led to an underestimation of SEA and TSST-1 by a factor over 2 (Fig. 4, A and B). As staphylococcal enterotoxins are reputed as poorly protease sensitive (15) and QconCAT concatemers are reported to be highly susceptible to trypsin digestion (9, 12), the straightforward rational for this underestimation is to postulate different digestion rates between the toxins and the QconCAT protein.
Quantification of Staphylococcal Superantigenic Toxins in Drinking Water Using Isotope-labeled PSAQ Standards—
Commercial SEA and TSST-1 toxins were added in defined amounts into drinking water samples. These samples were spiked with known quantities of SEA and TSST-1 PSAQ standards. The water samples were digested in solution, and nano-LC-MS data were analyzed as described for QconCAT. SEA and TSST-1 PSAQ standards generated 6 and 7 tryptic peptides, respectively. However, due to amino acid sequence similarity between staphylococcal superantigens and marked differences in nano-LC-MS detectability at low concentrations, only three and two labeled marker peptides were considered as highly specific standards for sensitive quantification of SEA and TSST-1 in drinking water, respectively (Fig. 5). Calibration with PSAQ standards was highly precise and improved the accuracy of measurements. Regarding SEA, the results obtained using the three standard peptides were highly consistent but slightly overestimated (slope values ranging from 1.26 to 1.42). This likely originated from the partial adsorption of SEA PSAQ standard onto vials during the dilution process. In the case of TSST-1, the two standard peptides LPTPIELPLK and QLAISTLDFEIR both allowed a recovery of 81% (slope value = 0.81).
|
|
| DISCUSSION |
|---|
|
|
|---|
The commercial availability of highly pure synthetic isotope-labeled peptides renders the AQUA peptide strategy very attractive. This methodology has been successfully used to quantify neuropeptides (25) or protein phosphorylations with phosphopeptide standards (5–7). However, individual chemical synthesis, purification, and quantification of isotope-labeled peptides make AQUA quantifications rather expensive. For this reason, proteins of interest are often quantified with a single AQUA peptide (26, 27). QconCAT and related polySIS proteins were developed as a smart strategy for multiplex absolute quantification of proteins (9–12). QconCAT constructions allow the parallel production and quantification of several (up to 100) peptides in a single experiment. Several marker peptides representing a single protein can be included. Once conceived, a QconCAT gene can easily be used for repeated production of unlimited amounts of isotope-labeled peptide standards. Interestingly, protein expression enables the synthesis of peptides difficult to produce by chemical methods such as peptides longer than 15 residues or peptides containing chemically reactive residues. According to Beynon et al. (9), QconCAT proteins should be especially suited for the assessment of stoichiometric ratios within protein complexes.
The AQUA and QconCAT strategies take advantage of identical chromatographic properties of an isotope-labeled peptide and its unlabeled equivalent in the reverse phase chromatography step of LC-MS analyses. However, for most biological samples, AQUA and QconCAT standards are generally added at late stages of the analytical process (6, 10). We questioned the biases introduced by prefractionation and digestion steps in AQUA and QconCAT quantifications. We hypothesized that the addition of full-length isotope-labeled recombinant proteins matching the biochemical properties of their corresponding protein targets into the biological samples before any processing would correct these potential biases. We thus developed an original PSAQ strategy based on the use of full-length isotope-labeled recombinant proteins as quantification standards. PSAQ standards are added into the biological samples before any processing to integrate the respective yields of prefractionation and digestion steps required for biomarkers analysis in complex samples. This approach therefore extends the principle of isotope dilution to the overall analytical process.
Compared with QconCAT, the important molecular biology tasks to develop each PSAQ standard may appear as a limitation of our strategy. However, from our experience, the molecular biology steps involved in the construction of a synthetic QconCAT gene are also time consuming. Comparatively, any normal length cDNA can be easily cloned into an expression vector in 2 labor days. Furthermore, artificial proteins like QconCAT concatemer have a strong tendency to aggregate as inclusion bodies and optimization of the chimeric protein expression can be a long way.
Metabolic isotope labeling is usually realized by in vivo expression in E. coli (9, 10, 28). However, in vivo, the metabolism of isotope-labeled precursors may result in a reduced incorporation yield and a dispersion of the label over different amino acids of the protein (label scrambling) (28) that potentially introduce important biases in MS quantification. Thus, we favored cell-free protein expression and labeling, which allow a high isotope incorporation yield (greater than 95%) with negligible scrambling (21, 29). (Supplemental Fig. 2). This technique is particularly suited to toxic proteins and allows an experimental confinement that is critical for biological and health hazard control.
In this study, we present an in depth comparison of the existing AQUA (5–8) and QconCAT strategies (9–12), to our original PSAQ methodology for biomarker quantification. The choice of staphylococcal superantigenic toxins SEA and TSST-1 as typical biomarkers that could be added to water or biological samples in defined amounts allowed a precise assessment of the accuracy of the three methods. With that goal in mind, we designed a set of AQUA peptides, a QconCAT concatemer and full-length isotope-labeled recombinant toxins (PSAQ standards) to quantify SEA and TSST-1 in drinking water and urine samples. In contaminated drinking water, two AQUA peptides addressing SEA gave diverging estimations (Fig. 2A). Moreover, two AQUA peptides markedly underestimated SEA and TSST-1 amounts (Fig. 2). Interestingly, similar observations have been reported for the quantification of C-reactive protein in serum using AQUA peptides (30). These biases mostly result from variabilities in trypsin digestion efficiency, which are not accounted for when AQUA peptides are used. When codigested with the targets, QconCAT standard gave more consistent results between the different marker peptides of a same protein. However, essentially due to differential susceptibility to proteolysis, QconCAT standard nonetheless led to an underestimation of the toxins (Fig. 4). Finally, the PSAQ strategy demonstrated a marked superiority over AQUA and QconCAT approaches for toxin quantification in drinking water both in terms of interpeptide consistency and accuracy (Fig. 5). The 26–42% overestimation of SEA abundance may originate from the adsorption of SEA PSAQ standard onto vials during the dilution process (final concentration before spiking: 10 nM). Accordingly, an excellent accuracy was observed for both SEA and TSST-1 titrations in urine samples (Fig. 6, B and C). In comparison with drinking water samples, the PSAQ standard solutions that were used for spiking urine samples were much more concentrated (200 nM), which may have prevented protein adsorption on vials.
For both QconCAT and AQUA strategies, the choice of the best peptide(s) to use for the quantification of any given protein is frequently based on an educated guess. Depending on biological matrix and prefractionation strategy, the choice of a single standard peptide can be inadequate (e.g. when the standard peptide is suppressed by other dominant peptides). The PSAQ strategy, which allows maximal protein coverage, circumvents these potential problems and provides a more robust quantification of the targets. As suggested by Anderson and Hunter (10) for small proteins, the difficulty to find a good peptide reporter can impose to swap trypsin for a distinct protease for peptide digestion. In a long term study, QconCAT or AQUA standards freeze the choice of quantification standards, whereas PSAQ strategy opens the way to alternative peptide standards.
The possibility to integrate the prefractionation and digestion yields renders PSAQ strategy exquisitely attractive for quantitative analysis of biomarkers in biological fluids. This improvement was demonstrated by the comparative quantification of SEA and TSST-1 toxins in a complex sample (e.g. urine) after Strataclean resin capture and SDS-PAGE prefractionation. Compared with drinking water samples, the protein complexity of urine samples generated high background and ionization competition that prevented MS detection of several toxin marker peptides. With the remaining markers, both AQUA and QconCAT severely underestimated the toxin amounts. The tendency of the AQUA strategy to underestimate protein targets was seriously aggravated after the SDS-PAGE prefractionation. This was also true for QconCAT despite our SDS-PAGE-compatible design. Finally, only PSAQ standards gave reliable quantification after this prefractionation protocol. Even with the most powerful MS technologies, decomplexification often appears as a mandatory step before quantification of medium to low abundance proteins (10, 13). Actually, AQUA quantifications are often realized on prefractionated protein samples (6, 23). As illustrated in the present study, uncertainty on the yield of the target protein recovery due to these prefractionation steps can introduce important quantification biases that are efficiently corrected using PSAQ standards. This constitutes the major advantage of the PSAQ strategy over AQUA and QconCAT approaches.
Improvement of detection sensitivity was beyond the scope of the present study. Nevertheless, the staphylococcal superantigenic toxins could be detected at the picomolar level in water samples using our LC-QTOF instrumentation. A reliable quantification of toxins could be achieved down to 3.8 pM (i.e. 0.5 fmol equivalent to 10 pg of TSST-1 in the 120 µl sample analyzed). This limit was comparable regardless of the standardization procedure used, e.g. AQUA, QconCAT, or PSAQ, and is inherent to the QTOF performances. For comparison, a recently developed real-time immuno-PCR technique detected SEA toxin down to 6 pg/100 µl (i.e. 2 pM) that is reportedly 100 times more sensitive than previous commercial toxin detection ELISA (31). In urine, due to the complexity of the matrix, QconCAT and PSAQ standards allowed quantification of SEA and TSST-1 down to the nanomolar range (i.e. 44 fmol equivalent to 1.2 ng in the actual 100 µl sample analyzed). This compares favorably with a previous report on staphylococcal SEB enterotoxin MS-based quantification (32), in which the limit of quantification of SEB spiked in apple juice was estimated to be 50 ng/ml. Thus, despite a much higher protein complexity of human urine compared with apple juice, we demonstrated a lower quantification limit in this complex matrix. This can be partly attributed to the difference of sensitivity of the LC-MS instrumentation used. In the near future, we intend to improve the sensitivity of our quantification procedure through the use of multiple reaction monitoring (MRM). The discriminating power of MRM assays renders them especially suited to address the protein complexity and high dynamic range of biological fluids such as urine (10, 33, 34). The lower density of species detected in nano-LC-MRM runs should enhance the robustness of the PSAQ quantification method. On this respect, the opportunity to monitor different peptide standards offered by the PSAQ strategy can be a compelling advantage compared with single peptide strategies. Along the same line, when using single peptide standards, any sequence variation or post-translational modification in a marker peptide will dismiss quantification of the corresponding protein. The larger protein coverage allowed by the PSAQ strategy can also favor the detection and differential quantification of variant species of any protein of interest. It is a valuable feature when addressing the survey of potentially variable proteins such as staphylococcal superantigenic toxins (35).
Conclusion—
We have demonstrated the advantages of our PSAQ strategy over existing approaches for biomarker absolute quantification in complex samples, such as biological fluids. Considering the high sensitivity of MS analyses, a single medium-scale, cell-free protein expression experiment provides sufficient amounts of a given PSAQ standard for thousands of quantification analyses. Moreover, simple quality controls, such as SDS-PAGE, coupled to quantitative fluorescent detection can be performed whenever required. In this regard, as it was realized for nuclear magnetic resonance structural studies (36), we propose to initiate a community-based effort for the construction of large reference PSAQ libraries for protein biomarkers. This could extend the actual standardization initiatives of the proteomic community to the developing fields of biomarkers discovery and validation by enabling truly accurate quantitative proteomics (37).
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
Published, MCP Papers in Press, September 11, 2007, DOI 10.1074/mcp.M700163-MCP200
1 The abbreviations used are: AQUA, Absolute Quantification; AAA, amino acid analysis; MRM, multiple reaction monitoring; PSAQ, protein standard absolute quantification; QconCAT, concatemer of standard peptides for absolute quantification; SEA, staphylococcal enterotoxin A; SEB, staphylococcal enterotoxin B; TSST-1, toxic shock syndrome toxin-1. ![]()
* This work was supported by a grant from Sanofi-Aventis France and Bayer Pharma as part of a multi-organism call for proposals. ![]()
The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
S The on-line version of this article (available at http://www.mcponline.org) contains supplemental material. ![]()

To whom corresponding should be addressed. Tel.: 334-38789657; Fax: 334-38785051; E-mail: virginie.brun{at}cea.fr
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
T. Fortin, A. Salvador, J. P. Charrier, C. Lenz, X. Lacoux, A. Morla, G. Choquet-Kastylevsky, and J. Lemoine Clinical Quantitation of Prostate-specific Antigen Biomarker in the Low Nanogram/Milliliter Range by Conventional Bore Liquid Chromatography-Tandem Mass Spectrometry (Multiple Reaction Monitoring) Coupling and Correlation with ELISA Tests Mol. Cell. Proteomics, May 1, 2009; 8(5): 1006 - 1015. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Gao, R. D. Holland, and L.-R. Yu Quantitative proteomics for drug toxicity Brief Funct Genomic Proteomic, April 7, 2009; (2009) elp006v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Ye, J. Blonder, and T. D. Veenstra Targeted proteomics for validation of biomarkers in clinical samples Brief Funct Genomic Proteomic, March 1, 2009; 8(2): 126 - 135. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-A. Hennekinne, V. Brun, M.-L. De Buyser, A. Dupuis, A. Ostyn, and S. Dragacci Innovative Application of Mass Spectrometry for the Characterization of Staphylococcal Enterotoxins Involved in Food Poisoning Outbreaks Appl. Envir. Microbiol., February 1, 2009; 75(3): 882 - 884. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| All ASBMB Journals | Journal of Biological Chemistry |
| Journal of Lipid Research | ASBMB Today |