Advertisement
MCP
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Originally published In Press as doi:10.1074/mcp.M700163-MCP200 on September 11, 2007.
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow All Versions of this Article:
M700163-MCP200v1
6/12/2139    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Glossary
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brun, V.
Right arrow Articles by Garin, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brun, V.
Right arrow Articles by Garin, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Molecular & Cellular Proteomics 6:2139-2149, 2007.
© 2007 by The American Society for Biochemistry and Molecular Biology, Inc.


Research

Isotope-labeled Protein Standards

Toward Absolute Quantitative Proteomics*,S

Virginie Brun{ddagger},§,{ddagger}{ddagger}, Alain Dupuis{ddagger},§, Annie Adrait{ddagger},§, Marlène Marcellin{ddagger},§, Damien Thomas||,**, Magali Court{ddagger},§, François Vandenesch||,** and Jérôme Garin{ddagger},§

From the {ddagger} Commissariat à l’Energie Atomique, DSV, iRTSV, Laboratoire d’Etude de la Dynamique des Protéomes, Grenoble, F-38054, France, § INSERM, U880, Grenoble, F-38054, France, Université Joseph Fourier, Grenoble, F-38054, France, || INSERM, U851, Immunité, Infection, Vaccination, Lyon, F-69008, France, and ** Faculté de Médecine Laennec, Université de Lyon, Lyon, F-69008, France


    ABSTRACT
 TOP
 ABSTRACT
 EXPERIMENTAL PROCEDURES
 RESULTS
 DISCUSSION
 REFERENCES
 
Diagnostic development and public health surveillance require technologies that provide specific identification and absolute quantification of protein biomarkers. Beside immunologically related techniques (e.g. enzyme-linked immunosorbent assay), MS is gaining increasing interest due to its high sensitivity and specificity. Furthermore, MS-based analyses are extremely accurate quantitatively, provided that suitable reference standards are available. Recently, the use of chemically synthesized isotope-labeled marker peptides for MS-based absolute quantification of proteins has led to major advances. However, we show here that the use of such peptides can lead to severe biases. In this work, we present an innovative strategy (Protein Standard Absolute Quantification) that uses in vitro-synthesized isotope-labeled full-length proteins as standards for absolute quantification. As those protein standards perfectly match the biochemical properties of the target proteins, they can be directly added into the samples to be analyzed, allowing a highly accurate quantification of proteins even in prefractionated complex samples. The power of our Protein Standard Absolute Quantification methodology for accurate absolute quantification of biomarkers was demonstrated both on water and urine samples contaminated with Staphylococcus aureus superantigenic toxins as typical biomarkers of public health interest.


Mass spectrometry MS has greatly contributed to the maturation of proteomics (1). It is now possible to characterize hundreds of proteins in an hour time frame and compare protein abundances in pairs of samples. The next frontier lies in accurate absolute quantitation. Although label-free spectral counting approaches (2, 3) are attracting considerable interest, robust absolute quantitative methodologies typically rely on the well-established isotope dilution principle (4), in which internal standardization is achieved with isotope-labeled homologs of specific proteolytic peptides from the target protein(s) (5, 6). The Absolute Quantitation (AQUA)1 peptide strategy uses chemically synthesized isotope-labeled peptides which are spiked into the samples in known quantities before MS analysis (58). Recently, the synthesis and metabolic labeling of an artificial concatemer of standard peptides (QconCAT), which can be spiked into the samples before trypsin digestion, was introduced to extend the number of quantified proteins (912). Although AQUA and QconCAT approaches have significantly advanced the quantitative measurement of proteins in biological samples, calibration with AQUA peptides and QconCAT constructs suffer from the following limitations: 1) a failure to take into account the actual efficiency of the proteolysis step required before MS analysis; 2) an incompatibility with sample prefractionation, which is often necessary when dealing with biological samples (13); and 3) a poor protein sequence coverage, limiting the statistical reliability of the quantification. We propose here an original Protein Standard Absolute Quantification (PSAQ) strategy for the absolute quantification of trace proteins in complex samples. This strategy is based on the use of in vitro-synthesized isotope-labeled full-length proteins as standards for quantification. To validate our methodology, we compared it with the two alternatives, AQUA and QconCAT strategies, using Staphylococcus aureus superantigenic toxins in water and urine samples as typical biomarkers of public health concern (14, 15).

S. aureus superantigenic toxins (enterotoxins and toxic shock syndrome toxin-1 [TSST-1]) are virulence factors responsible for severe diseases in humans among which the highly lethal staphylococcal toxic shock syndrome (14, 15). Staphylococcal toxic shock syndrome is related to the ability of enterotoxins and TSST-1 to polyclonally and extensively activate T cells at picomolar concentrations, a property referred to as superantigenicity. Besides their superantigenic activity, staphylococcal enterotoxins also display specific emetic properties and constitute a major cause of food poisoning (15). For all these reasons, staphylococcal enterotoxins constitute a significant threat as biological weapons. The Center for Disease Control has registered the staphylococcal enterotoxin B (SEB) as a potential warfare contaminant of food and water supplies. To date, 19 staphylococcal enterotoxins have been identified (variant forms excluded) and are associated with different clinical profiles (1517). Extensive sequence and structure similarities between staphylococcal superantigenic toxins have so far precluded the development of specific and comprehensive immunological tools. As a result, no diagnostic test is presently available for the staphylococcal toxic shock syndrome. Furthermore, no assay is referenced for the identification and quantification of these toxins in accidentally or deliberately contaminated food or water supplies. In this context, MS, which circumvents the need for antibodies, offers great potential for staphylococcal superantigenic toxin-specific detection and quantification.

In this work, we present an MS-based methodology to detect and quantify the staphylococcal superantigenic toxins SEA and TSST-1, which are the most frequently involved toxins in staphylococcal toxic shock syndrome (15, 16). Drinking water and human urine were selected as preferred matrices for warfare agent surveillance and clinical diagnosis. Comparisons with the current state-of-the-art methodologies demonstrate the great potential of isotope-labeled full-length proteins as standards for MS-based absolute quantification.


    EXPERIMENTAL PROCEDURES
 TOP
 ABSTRACT
 EXPERIMENTAL PROCEDURES
 RESULTS
 DISCUSSION
 REFERENCES
 
Chemicals and Reagents—
AQUA [13C6, 15N] L-leucine-labeled peptides were synthesized by Sigma-Genosys (Saint Quentin Fallavier, France). These peptides were quantified by amino acid analysis (AAA) by the provider. Recombinant staphylococcal enterotoxins SEA and TSST-1 were purchased from Toxin Technology (Sarasota, FL). The dilutions of quantification standards and commercial toxins were systematically performed in low adsorption tubes (Dutscher, Brumath, France).

Synthesis, Purification, and Quantification of the Isotope-labeled QconCAT Concatemer—
The QconCAT protein was designed as shown in Fig. 1. Briefly, tryptic peptides from eight staphylococcal superantigenic toxins (SEA, SEB, TSST-1, staphylococcal enterotoxin G, staphylococcal enterotoxin I, staphylococcal enterotoxin M, staphylococcal enterotoxin N, and staphylococcal enterotoxin O) were selected according to their uniqueness of sequence among the staphylococcal superantigens and their detectability in nano-LC-MS analysis. These peptide sequences were concatened into an artificial QconCAT protein and retro-translated to design the corresponding artificial QconCAT gene (see references 9 and 11 for more details). The QconCAT gene was synthesized from 53 5' phosphorylated oligonucleotides (Sigma-Genosys) covering the forward and reverse strands (Supplemental Fig. 1). The synthetic QconCAT gene was assembled by ligase chain reaction with TaqDNA ligase (New England Biolabs, Frankfurt, Germany) and amplified with the Expand High Fidelity polymerase (Roche, Meylan, France) using the primers mentioned in Supplemental Table I. The amplified QconCAT gene was purified, digested with NcoI (Roche) and SmaI (New England Biolabs), and inserted into the pIVEX 2.3d vector (Roche) providing a C-terminal hexahistidine purification tag. Ligation was achieved using the Rapid DNA Ligation Kit (Roche). The resulting plasmid was cloned into strain XL1-Blue (Stratagene, Amsterdam, Nederlands) and was purified using QIAprep Spin Miniprep Kit (Qiagen, Courtaboeuf, France). Finally, we checked the QconCAT construct sequence before its use for recombinant protein synthesis (Genome Express, Meylan, France). QconCAT protein production was performed in vitro using the RTS 500 ProteoMaster Escherichia coli HY Kit (Roche) according to the manufacturer's instructions with the following modifications: we used the RTS Amino Acid Sampler Kit (Roche) instead of the amino acid mix provided, and we replaced L-lysine and L-arginine by isotope-labeled [13C6, 15N2] L-lysine and [13C6, 15N4] L-arginine (Cambridge Isotope Laboratories, Andover, MA). The isotope enrichment of [13C6, 15N2] L-lysine and [13C6, 15N4] L-arginine was 98% 13C and 98% 15N. QconCAT protein was efficiently produced in a precipitated form and was solubilized in guanidine 6N. QconCAT purification was performed on a nickel affinity column (Ni Sepharose 6 Fast Flow, Amersham Biosciences, Freiburg, Germany) using a 20 mM-250 mM imidazole gradient in guanidine 6N. After purification, QconCAT was sequentially dialyzed against pure water and 1% SDS, Tris HCl 50 mM, pH 7.5. QconCAT quantification was performed by AAA on a Biochrom 30 Amino Acid Analyser (Biochrom, Cambridge, UK). QconCAT primary structure and isotope labeling was further assessed by nano-LC-MS/MS and nano-LC-MS analysis (Supplemental Fig. 2).


Figure 1
View larger version (29K):
[in this window]
[in a new window]

 
FIG. 1. QconCAT concatemer design, production and analysis. A, the QconCAT concatemer designed to generate stable isotope-labeled standards for staphylococcal superantigenic toxins. This artificial protein was constructed according to the strategy of Beynon et al. (9). The toxins targeted in the present study are SEA and TSST-1. For each of these two toxins, three peptide sequences corresponding to three tryptic marker peptides were included in the QconCAT concatemer (peptides P1-P3 for SEA and P7-P9 for TSST-1). We also added eight peptide standards for the quantification of other staphylococcal enterotoxins. These supplementary standard peptides were not used for quantification in the present study. The quantification peptide (QP) was introduced in the construct following the design of Beynon et al. (9). However, quantification based on the unique cysteine residue of this tag proved poorly reliable due to interprotein disulfide formation. Thus, we favored the more robust AAA quantification. After purification and cleavage of the purification hexahistidine tag, the purity of in vitro produced QconCAT was checked by SDS-PAGE (B). Finally, using MALDI-TOF (C) or nano-LC-QTOF, 13 of the standard peptides could be assigned on a digest of the pure QconCAT protein.

 
Synthesis, Purification, and Quantification of Isotope-labeled SEA and TSST-1 PSAQ Standards—
Two S. aureus strains carrying SEA or TSST-1 gene were selected from the strain collection of the French National Staphylococci Reference Center. Isotope-labeled SEB standard was not synthesized as its production is officially restricted. Genomic DNA was prepared using the QIAamp DNA Stool Mini Kit (Qiagen). The primers used for PCR amplification are described in Supplemental Table I. SEA and TSST-1 PCR fragments were purified, digested with KspI (Roche) and SmaI (New England Biolabs), and cloned into the pIVEX 2.4d expression vector providing an N-terminal cleavable hexahistidine purification tag (Roche). Our PSAQ strategy relies on biochemical equivalence between each toxin and its PSAQ standard. We thus privileged an N terminus cleavable tag to allow a polishing of the limited N terminus heterogeneity reported for proteins produced by cell-free synthesis (18). These constructs were cloned in Xl1 blue, purified, sequenced, and used for in vitro protein synthesis in the presence of [13C6, 15N2] L-lysine and [13C6, 15N4] L-arginine as described above for QconCAT. Isotope-labeled SEA and TSST-1 were readily produced in a soluble form and were purified on a nickel affinity column (Ni Sepharose 6 Fast Flow, Amersham Biosciences) using an imidazole gradient. The N-terminal hexahistidine tag of each isotope-labeled protein was cleaved by biotinylated Factor Xa (Factor Xa Removal Kit, Roche) according to the manufacturer's instructions. Both the resulting hexahistidine tag peptide and the biotinylated Factor Xa were removed in a single step using a mix of streptavidin coated beads and Ni Sepharose 6 Fast Flow resin. These isotope-labeled SEA and TSST-1 were quantified by AAA. Primary structure of the proteins and labeling efficiency were verified by nano-LC-MS/MS and nano-LC-MS analysis. The incorporation yield of [13C6, 15N2]-lysine and [13C6, 15N4]-arginine in these cell-free expressed standards was greater than 98% (data not shown).

SDS-PAGE Quality Control—
Home-produced PSAQ proteins and purchased SEA and TSST-1 were all checked for purity on SDS-PAGE using both Imperial Protein Stain and SYPRO Ruby staining (Bio-Rad, Marnes-la-Coquette, France). The quantities of commercial toxins were too limited for AAA analysis, and commercial TSST-1 toxin displayed a contamination by a higher molecular weight protein precluding an accurate AAA quantification. Thus, commercial toxin concentrations were evaluated by comparison with our AAA calibrated PSAQ standards on SDS-PAGE using SYPRO Ruby staining (19). SYPRO Ruby fluorescence was scanned (Laser 532 nm, filter 610BP30) on a Typhoon 9400 (Amersham Biosciences). When compared with our AAA calibrated PSAQ standards, the announced concentrations of commercial SEA and TSST toxins turned out to be overestimated (Supplemental Fig. 3). Therefore, the commercial toxin concentrations were corrected, and the corrected values were used in all subsequent calculations.

Water Sample Preparation and Trypsin Digestion for MS Analyses—
Drinking water samples were contaminated with five different quantities of SEA and TSST-1 commercial toxins. Each sample was divided into nine aliquots of 120 µl each. Three aliquots (analytical replicates) of each sample were spiked with either QconCAT or PSAQ toxins standards in defined quantities. Trypsin digestion was performed in solution using sequencing grade modified trypsin (Promega, Madison, WI) at a 1:2 protease to toxins ratio in 25 mM NH4HCO3 overnight at 37 °C. Samples were dried by vacuum centrifugation and resolubilized in 5% ACN, 0.2% formic acid. Before nano-LC-MS analysis, AQUA peptides were added in defined quantities into the aliquots that contained neither QconCAT nor PSAQ standards.

Urine Sample Preparation and Trypsin Digestion for MS Analyses—
Urine from a 30-year-old healthy woman was collected and contaminated with four different quantities of SEA and TSST-1 commercial toxins. Each sample was divided into nine aliquots of 100 µl each. Three aliquots (analytical replicates) of each sample were contaminated with PSAQ toxin standards in defined amounts. Each 100 µl aliquot was adsorbed on 5 µl of Strataclean resin (Stratagene) according to the manufacturer's instructions. Following elimination of supernatant, proteins adsorbed onto the resin were directly eluted in 10 µl of a depolymerization buffer containing 2% SDS and 5% β-mercaptoethanol. At this stage, QconCAT standard was added in controlled quantities into half of the samples devoid of PSAQ standards. After a thermal denaturation step at 95 °C for 5 min, samples were loaded on precast Novex NuPAGE Bis–Tris gels (4–12% acrylamide gradient) purchased from Invitrogen (Cergy Pontoise, France). Gels were run for 30 min under 200 V, fixed for 30 min in 30% ethanol-7.5% acetic acid, and stained with Biosafe Coomassie blue (Bio-Rad). In the 25 kDa region of the gel encompassing toxins and QconCAT, protein bands were excised and were destained by repeated cycles of incubation in 25 mM NH4HCO3 for 15 min and then with 50% (v/v) ACN in the same buffer (25 mM NH4HCO3) for 15 min. After drying by vacuum centrifugation, the gel pieces were incubated with an oxidizing solution (7% H2O2) for 15 min (20). Gel pieces were then washed in HPLC grade water (Sigma-Aldrich) for 15 min before being dehydrated with 100% ACN. In-gel digestion was performed using 1:2 trypsin to protein ratio (sequencing grade modified trypsin, Promega) in 25 mM NH4HCO3 overnight at 37 °C. Peptides were extracted from the gel using passive diffusion in the following solutions: 50% ACN, then 5% formic acid, and finally 100% ACN. The extracts were dried by vacuum centrifugation, and peptides were resolubilized in 5% ACN, 0.2% formic acid. Before nano-LC-MS analysis, controlled amounts of AQUA peptides were added to the samples that had not been spiked with PSAQ or QconCAT standards.

Nano-LC-MS and Nano-LC-MS/MS Analyses—
MS analyses were performed on a nano-LC system coupled to a QTOF Ultima mass spectrometer (Waters, Milford, MA). Briefly, peptide digests were first concentrated on a 300 µm x 5 mm PepMap C18 precolumn (LC-Packings-Dionex, Sunnyvale, CA). Peptide digests were then passed onto a C18 column (75 µm x 150 mm) (LC-Packings-Dionex) and eluted with a gradient from 10% ACN, 0.1% formic acid to 80% ACN, 0.08% formic acid (run duration 60 min, flow rate 200 nl/min). The mass spectrometer was operated in the positive ion electrospray ionization mode with a resolution of 9000 to 11,000 full-width half-maximum. Data-dependent analysis was used for MS/MS (three most abundant ions in each cycle): 1 s MS (m/z 400–1600) and maximum 4 s MS/MS (m/z 50–2000, continuum mode) with 2 min dynamic exclusion. MS/MS raw data were processed using MassLynx 4.0 software (smooth 3/2 Savitzky Golay) (Waters). Peptide identifications from the resulting MS/MS dataset were achieved using an in-house MASCOT server (version 2.0) (Matrix Sciences, London). Full specifications of search parameters are presented in supplemental data files. Quantification was done manually from nano-LC-MS data after integration of peaks for unlabeled/labeled peptide pairs on reconstituted chromatograms obtained by extraction of a specific mass (±0.1 Da) with MassLynx 4.0 software. The minimum signal to noise ratio considered for quantitation was 15:1.


    RESULTS
 TOP
 ABSTRACT
 EXPERIMENTAL PROCEDURES
 RESULTS
 DISCUSSION
 REFERENCES
 
Selection of Staphylococcal Superantigenic Toxin Marker Peptides—
SEA and TSST-1 recombinant staphylococcal toxins were submitted to SDS-PAGE and in-gel digestion with trypsin. The peptide digests were analyzed by nano-LC-MS/MS (see Supplemental data files) and nano-LC-MS. Specific tryptic peptides (marker peptides) were selected for each of the two toxins (Table I). Marker peptides were chosen according to their sequence uniqueness among staphylococcal superantigens and their optimal detectability in MS analysis. Three of these marker peptides were made synthesized as AQUA peptides with one [13C6, 15N] L-leucine (mass increase 7 Da).


View this table:
[in this window]
[in a new window]

 
TABLE I Marker peptides used for the detection and quantification of SEA and TSST-1 staphylococcal superantigenic toxins.

 
Quantification of Staphylococcal Superantigenic Toxins in Drinking Water Using Isotope-labeled AQUA Peptides—
Commercial SEA and TSST-1 staphylococcal toxins were added in defined amounts into drinking water. Trypsin digestion was performed in-solution. Known amounts of AQUA peptides were added to the peptide digests before nano-LC-MS analysis. For the three unlabeled/labeled peptide pairs selected (Table I), peak doublets separated by a mass of {Delta}m = 7 Da ([13C6, 15N] L-leucine peptides) were observed in the MS survey. Each of these peak doublets was integrated to determine the total ion signal of the natural peptide (mass m) and its corresponding labeled AQUA standard (mass m + {Delta}m). The ratio of these signals allowed a direct calculation of the estimated natural toxin amount which was plotted against the added amount (Fig. 2). Ideally, 100% recovery should have been observed. The SEA and TSST-1 titration curves obtained were linear for added amounts of toxins ranging from 50 to 750 pg. Deviation from linearity above these values resulted from ion signal saturation. The measurements of accuracy and precision were evaluated through the slope values of the titration curves and the standard mean errors (S.E.) values of the data, respectively. AQUA peptide standardization is a highly precise quantification strategy (Fig. 2). However, regarding accuracy, an important discrepancy between the two AQUA peptides targeting SEA was observed (slope value = 1.37 for YNLYNSDVFDGK peptide and slope value = 0.44 for NVTVQELDQAR peptide) (Fig. 2A). Three potentials biases may account for such results: 1) AQUA peptides were quantified by the provider using AAA, obtained lyophilized, and re-solubilized according to the provider's own guidelines. Nevertheless, quantitative re-solubilization should not be taken for granted, and a subsequent evaluation of the re-solubilized peptide by AAA would require much more material than provided. 2) AQUA standards have to be highly diluted prior to their addition into the samples. Depending on their physicochemical properties, dilution of pure peptides can lead to important losses of peptide by adsorption onto vials. 3) Standardization with AQUA peptides does not take into account the yield of the protease digestion step. This step introduces variability due to the intrinsic susceptibility of each protein or protein domain to proteolysis. In addition, variability between samples can also originate from the digestion conditions (e.g. composition of the sample buffer, amount of trypsin, temperature during incubation). Standard peptide adsorption onto vials or incomplete solubilization both lead to an overestimation of the true standard concentration and consequently of the targeted protein. Accordingly, the 37% overestimation of SEA abundance given by the AQUA peptide YNLYNSDVFDGK (slope value = 1.37) likely resulted from incomplete re-solubilization and/or partial adsorption of this standard peptide onto vials. Conversely, the peptides NVTVQELDQAR and LPTPIELPLK may not have been efficiently generated by trypsin digestion and therefore led to an important underestimation of SEA and TSST-1 abundances (slope values = 0.44 and 0.54, respectively). This stresses a major limitation of the AQUA peptide strategy: it does not take into account the actual digestion yield of the different peptides from the native protein. Actually, this drawback is especially problematic for proteins such as staphylococcal superantigenic toxins, which are known to be poorly protease sensitive (15).


Figure 2
View larger version (12K):
[in this window]
[in a new window]

 
FIG. 2. Quantification of SEA and TSST-1 staphylococcal toxins in drinking water samples using AQUA peptides. Variable amounts of SEA and TSST-1 were diluted in drinking water and digested in solution with trypsin. After digestion, known amounts of [13C6, 15N]-leucine (*) AQUA standards were added, and the samples were analyzed by nano-LC-MS. The extracted ion chromatogram signals from the unlabeled/labeled peptide doublets ({Delta}m = 7 Da) were integrated, and their ratio was used to estimate the amount of natural toxin added. SEA (A) and TSST-1 (B) titration curves were obtained by plotting the estimate amount of toxin against the added amount. The marker peptides considered for each titration are mentioned. Values calculated from saturated MS-signals are presented as open data points ({diamond} and {triangleup}). Each data point is the mean value ± S.E. of three analytical replicates.

 
Quantification of Staphylococcal Superantigenic Toxins in Drinking Water Using Isotope-labeled QconCAT Protein—
We designed and produced an isotope-labeled concatemer of staphylococcal superantigenic toxins marker peptides (QconCAT) (Fig. 1A and B). In this construction, we included all the peptides previously chosen as AQUA standards. The presence of multiple peptide standards for each toxin aimed at improving the quantification robustness. When QconCAT was digested and analyzed, among the 14 marker peptides theoretically generated, 11 were detected by MALDI-TOF analysis (Fig. 1C) and 13 were observed in nano-LC-MS analysis (data not shown). The remaining peptide (peptide P11, Fig. 1A) was not observed in nano-LC-MS analyses possibly due to its high hydrophobicity.

In agreement with previous reports (21), the cell-free expression of QconCAT in the presence of [13C6, 15N2]-lysine and [13C6, 15N4]-arginine yielded a high rate of isotope-label incorporation. A nano-LC-MS analysis of the pure isotope-labeled QconCAT indicated an isotopic purity greater than 98% (Supplemental Fig. 2). Moreover, [13C6, 15N2]-lysine and [13C6, 15N4]-arginine-labeling leads to constant mass increments of arginyl and lysyl peptides after trypsin cleavage, which greatly simplifies the processing of LC-MS data required for quantification. Therefore, for each of the marker peptides selected (Table I), peak doublets separated by a mass of 8 Da ([13C6, 15N2]-lysine-labeled peptides) or 10 Da [13C6, 15N4]-arginine-labeled peptides) were investigated. The ratios of unlabeled over labeled peptide signals allowed a direct calculation of the estimated natural toxin amount that was plotted against the added amount (Figs. 3 and 4).


Figure 3
View larger version (19K):
[in this window]
[in a new window]

 
FIG. 3. Comparative use of predigested or codigested QconCAT standard. Variable amounts of SEA and TSST-1 were mixed into drinking water samples, and QconCAT concatemer was used as calibration standard. The contaminated water samples were digested in solution with trypsin either separately ({diamond}) or concomitantly ({blacktriangleup}) with QconCAT. We show here the titration curves obtained with the marker peptides YNLYNSDVFDGK (A), NVTVQELDLQAR (B) and QNTVPLETVK (C) addressing SEA and LPTPIELPLK (D) addressing TSST-1. Each data point is the mean value ± S.E. of three analytical replicates.

 

Figure 4
View larger version (12K):
[in this window]
[in a new window]

 
FIG. 4. Quantification of SEA and TSST-1 in drinking water samples using QconCAT. Drinking water samples were contaminated with different amounts of SEA and TSST-1. QconCAT concatemer was added to the samples and codigested in solution with the toxins. The peptides generated by QconCAT digestion were used as calibration standards in nano-LC-MS analysis. Three marker peptides (mentioned) enabled the titration of SEA (A), and one peptide allowed that of TSST-1 (B). Each data point is the mean value ± S.E. of three analytical replicates.

 
We showed from the previous AQUA titrations that the tryptic digestion efficiency influenced the quantification accuracy. The intrinsic susceptibility of proteins to proteolysis and the experimental conditions of the digestion may constitute major influencing parameters. In an attempt to underline the role of proteolysis conditions, two experiments were designed with the QconCAT chimeric protein. In the first experiment, QconCAT was added in known amounts into drinking water samples and was codigested with the toxins. In the second experiment, QconCAT was digested separately, and the resulting digest was used as a mixture of standard peptides to calibrate the toxin digests. As shown in Fig. 3, poor linearity and high S.E. were obtained when the QconCAT standard was digested separately. These results emphasize the benefits of codigesting the standard with the target proteins for linear and reproducible quantitations.

Therefore, in subsequent experiments aimed at quantifying SEA and TSST-1 in drinking water, the QconCAT standard was codigested with the artificially contaminated samples. Although the six marker peptides could be observed in nano-LC-MS analysis, they exhibited quite different MS detectability. To enhance quantification sensitivity, we focused on the four marker peptides that gave the best nano-LC-MS signals (NVTVQELDLQAR, QNTVPLETVK, YNLYNSDVFDGK for SEA, and LPTPIELPLK for TSST-1). In contrast with SEA titrations obtained with the two AQUA peptides YNLYNSDVFDGK and NVTVQELDLQAR, the three QconCAT-generated SEA peptide standards displayed only limited variance (compare Fig. 2A and Fig. 4A). This higher consistency is attributed to the equi-stoichiometric representation of peptide standards in the QconCAT construct. However, QconCAT quantifications led to an underestimation of SEA and TSST-1 by a factor over 2 (Fig. 4, A and B). As staphylococcal enterotoxins are reputed as poorly protease sensitive (15) and QconCAT concatemers are reported to be highly susceptible to trypsin digestion (9, 12), the straightforward rational for this underestimation is to postulate different digestion rates between the toxins and the QconCAT protein.

Quantification of Staphylococcal Superantigenic Toxins in Drinking Water Using Isotope-labeled PSAQ Standards—
Commercial SEA and TSST-1 toxins were added in defined amounts into drinking water samples. These samples were spiked with known quantities of SEA and TSST-1 PSAQ standards. The water samples were digested in solution, and nano-LC-MS data were analyzed as described for QconCAT. SEA and TSST-1 PSAQ standards generated 6 and 7 tryptic peptides, respectively. However, due to amino acid sequence similarity between staphylococcal superantigens and marked differences in nano-LC-MS detectability at low concentrations, only three and two labeled marker peptides were considered as highly specific standards for sensitive quantification of SEA and TSST-1 in drinking water, respectively (Fig. 5). Calibration with PSAQ standards was highly precise and improved the accuracy of measurements. Regarding SEA, the results obtained using the three standard peptides were highly consistent but slightly overestimated (slope values ranging from 1.26 to 1.42). This likely originated from the partial adsorption of SEA PSAQ standard onto vials during the dilution process. In the case of TSST-1, the two standard peptides LPTPIELPLK and QLAISTLDFEIR both allowed a recovery of 81% (slope value = 0.81).


Figure 5
View larger version (12K):
[in this window]
[in a new window]

 
FIG. 5. Quantification of SEA and TSST-1 in drinking water samples using PSAQ standards. Variable amounts of SEA and TSST-1 were mixed into drinking water samples. PSAQ toxin standards were added as calibration references. The contaminated water samples were digested in solution with trypsin. The peptides generated by PSAQ toxins digestion were used as quantification references in nano-LC-MS analysis. SEA (A) and TSST-1 (B) could be titrated with three and two marker peptides (mentioned), respectively. Each data point is the mean value ± S.E. of three analytical replicates.

 
Quantification of Staphylococcal Superantigenic Toxins in Prefractionated Urine—
In the final set of experiments, we contaminated human urine samples with SEA and TSST-1, which are the most frequently involved toxins in staphylococcal toxic shock syndrome (15, 16). Contaminated samples were prefractionated on Strataclean resin, decomplexified by SDS-PAGE, and digested in-gel with trypsin. These samples were spiked with either PSAQ toxins, or QconCAT concatemer, or AQUA peptides (Fig. 6A). The PSAQ standards were directly added in known quantities into the urine samples. Regarding QconCAT standard, we improved the previously described QconCAT concept (9) by adjusting its molecular weight to that of the target toxins (24 kDa), so that: 1) it comigrates with the toxin targets in an electrophoresis gel, 2) it is codigested in-gel with the toxins, and 3) the peptides generated by QconCAT and toxin proteolysis are concomitantly extracted from the gel. The adjustment of QconCAT to 24 kDa was accomplished by incorporation of additional peptides potentially useful as quantification standards for other staphylococcal superantigenic toxins (Fig. 1, other toxins not quantified in the present study). As the QconCAT construct was solubilized in 1% SDS, it could not be captured on Strataclean resin. Consequently, it was introduced into the samples just before SDS-PAGE. The AQUA peptides standards, the size of which imposes their addition after SDS-PAGE fractionation step, were added to the samples just before nano-LC-MS analysis as previously described (6).


Figure 6
View larger version (28K):
[in this window]
[in a new window]

 
FIG. 6. Comparison of AQUA peptides, QconCAT concatemer, and PSAQ standards for the quantification of SEA and TSST-1 in urine samples. Urine samples were contaminated with different amounts of SEA and TSST-1. Three types of standards were used for toxin quantification: AQUA peptides, QconCAT concatemer, and PSAQ toxins. These standards were added to the samples at different stages of the analysis process (A). The comparison of the three isotope dilution methods for the titration of SEA (peptide NVTVQELDLQAR) (B) and TSST-1 (peptide LPTPIELPLK) (C) is reported. Each data point is the mean value ± S.E. of three analytical replicates.

 
In comparison with the detection and quantification of SEA and TSST-1 in drinking water samples, lower sequence coverage was obtained in urine samples even when the PSAQ standards were used. Indeed, a high background generated by urinary proteins prevented the detection of marker peptides QNTVPLETVK and YNLYNSDVFDGK. In drinking water, toxins were quantitated down to 7.7 pM (signal-to-noise ratio 75:1) for SEA and 3.8 pM (signal-to-noise 15:1) for TSST-1, respectively. In contrast, the high protein complexity limited the quantitation sensitivity in urine to 0.4 nM (signal-to-noise ratio 35:1) for SEA and to 1.3 nM (signal-to-noise ratio 20:1) for TSST-1. Fig. 6 shows the estimates of SEA and TSST-1 amounts obtained with the different standards compared with the added amounts. Both AQUA and QconCAT standardizations severely underestimated the toxin amounts in urine. This is due to addition of these standards at late stages of the analytical process (Fig. 6A). This emphasizes a major limitation of these strategies: their incompatibility with sample prefractionation. In contrast, PSAQ was the only quantitation strategy that allowed an accurate estimation of the toxins in this complex matrix (slope values = 1.05 and 1.08 for SEA marker peptide NVTVQELDLQAR and TSST-1 marker peptide LPTPIELPLK, respectively) (Fig. 6, B and C).


    DISCUSSION
 TOP
 ABSTRACT
 EXPERIMENTAL PROCEDURES
 RESULTS
 DISCUSSION
 REFERENCES
 
In various fields ranging from fundamental biology to clinical diagnostic and public health surveillance, the specific and accurate quantification of proteins in complex biological samples remains a recurrent and challenging problem. For many protein biomarkers, this problem has been solved by immunological techniques. However, the success of immunological approaches relies on the heavy duty production and validation of high specificity and high affinity antibodies. Although recent efforts are being made to design antibody arrays (22), the adaptation of immunological methods to multiplexed analyses remains limited. Indeed, the simultaneous optimization of several protein assays is hardly ever possible (23). Alternatively, the power of MS-based proteomics can be harnessed to allow proteome-wide quantifications. Label-free spectral counting approaches have been especially designed for this purpose (2, 3). However, so far, the low cost and high potential of these approaches for large scale studies are counterbalanced by their rather poor accuracy. To gain in measurement accuracy, absolute quantitative methodologies still require an internal standardization via stable isotope dilution strategies (6, 24).

The commercial availability of highly pure synthetic isotope-labeled peptides renders the AQUA peptide strategy very attractive. This methodology has been successfully used to quantify neuropeptides (25) or protein phosphorylations with phosphopeptide standards (57). However, individual chemical synthesis, purification, and quantification of isotope-labeled peptides make AQUA quantifications rather expensive. For this reason, proteins of interest are often quantified with a single AQUA peptide (26, 27). QconCAT and related polySIS proteins were developed as a smart strategy for multiplex absolute quantification of proteins (912). QconCAT constructions allow the parallel production and quantification of several (up to 100) peptides in a single experiment. Several marker peptides representing a single protein can be included. Once conceived, a QconCAT gene can easily be used for repeated production of unlimited amounts of isotope-labeled peptide standards. Interestingly, protein expression enables the synthesis of peptides difficult to produce by chemical methods such as peptides longer than 15 residues or peptides containing chemically reactive residues. According to Beynon et al. (9), QconCAT proteins should be especially suited for the assessment of stoichiometric ratios within protein complexes.

The AQUA and QconCAT strategies take advantage of identical chromatographic properties of an isotope-labeled peptide and its unlabeled equivalent in the reverse phase chromatography step of LC-MS analyses. However, for most biological samples, AQUA and QconCAT standards are generally added at late stages of the analytical process (6, 10). We questioned the biases introduced by prefractionation and digestion steps in AQUA and QconCAT quantifications. We hypothesized that the addition of full-length isotope-labeled recombinant proteins matching the biochemical properties of their corresponding protein targets into the biological samples before any processing would correct these potential biases. We thus developed an original PSAQ strategy based on the use of full-length isotope-labeled recombinant proteins as quantification standards. PSAQ standards are added into the biological samples before any processing to integrate the respective yields of prefractionation and digestion steps required for biomarkers analysis in complex samples. This approach therefore extends the principle of isotope dilution to the overall analytical process.

Compared with QconCAT, the important molecular biology tasks to develop each PSAQ standard may appear as a limitation of our strategy. However, from our experience, the molecular biology steps involved in the construction of a synthetic QconCAT gene are also time consuming. Comparatively, any normal length cDNA can be easily cloned into an expression vector in 2 labor days. Furthermore, artificial proteins like QconCAT concatemer have a strong tendency to aggregate as inclusion bodies and optimization of the chimeric protein expression can be a long way.

Metabolic isotope labeling is usually realized by in vivo expression in E. coli (9, 10, 28). However, in vivo, the metabolism of isotope-labeled precursors may result in a reduced incorporation yield and a dispersion of the label over different amino acids of the protein (label scrambling) (28) that potentially introduce important biases in MS quantification. Thus, we favored cell-free protein expression and labeling, which allow a high isotope incorporation yield (greater than 95%) with negligible scrambling (21, 29). (Supplemental Fig. 2). This technique is particularly suited to toxic proteins and allows an experimental confinement that is critical for biological and health hazard control.

In this study, we present an in depth comparison of the existing AQUA (58) and QconCAT strategies (912), to our original PSAQ methodology for biomarker quantification. The choice of staphylococcal superantigenic toxins SEA and TSST-1 as typical biomarkers that could be added to water or biological samples in defined amounts allowed a precise assessment of the accuracy of the three methods. With that goal in mind, we designed a set of AQUA peptides, a QconCAT concatemer and full-length isotope-labeled recombinant toxins (PSAQ standards) to quantify SEA and TSST-1 in drinking water and urine samples. In contaminated drinking water, two AQUA peptides addressing SEA gave diverging estimations (Fig. 2A). Moreover, two AQUA peptides markedly underestimated SEA and TSST-1 amounts (Fig. 2). Interestingly, similar observations have been reported for the quantification of C-reactive protein in serum using AQUA peptides (30). These biases mostly result from variabilities in trypsin digestion efficiency, which are not accounted for when AQUA peptides are used. When codigested with the targets, QconCAT standard gave more consistent results between the different marker peptides of a same protein. However, essentially due to differential susceptibility to proteolysis, QconCAT standard nonetheless led to an underestimation of the toxins (Fig. 4). Finally, the PSAQ strategy demonstrated a marked superiority over AQUA and QconCAT approaches for toxin quantification in drinking water both in terms of interpeptide consistency and accuracy (Fig. 5). The 26–42% overestimation of SEA abundance may originate from the adsorption of SEA PSAQ standard onto vials during the dilution process (final concentration before spiking: 10 nM). Accordingly, an excellent accuracy was observed for both SEA and TSST-1 titrations in urine samples (Fig. 6, B and C). In comparison with drinking water samples, the PSAQ standard solutions that were used for spiking urine samples were much more concentrated (200 nM), which may have prevented protein adsorption on vials.

For both QconCAT and AQUA strategies, the choice of the best peptide(s) to use for the quantification of any given protein is frequently based on an educated guess. Depending on biological matrix and prefractionation strategy, the choice of a single standard peptide can be inadequate (e.g. when the standard peptide is suppressed by other dominant peptides). The PSAQ strategy, which allows maximal protein coverage, circumvents these potential problems and provides a more robust quantification of the targets. As suggested by Anderson and Hunter (10) for small proteins, the difficulty to find a good peptide reporter can impose to swap trypsin for a distinct protease for peptide digestion. In a long term study, QconCAT or AQUA standards freeze the choice of quantification standards, whereas PSAQ strategy opens the way to alternative peptide standards.

The possibility to integrate the prefractionation and digestion yields renders PSAQ strategy exquisitely attractive for quantitative analysis of biomarkers in biological fluids. This improvement was demonstrated by the comparative quantification of SEA and TSST-1 toxins in a complex sample (e.g. urine) after Strataclean resin capture and SDS-PAGE prefractionation. Compared with drinking water samples, the protein complexity of urine samples generated high background and ionization competition that prevented MS detection of several toxin marker peptides. With the remaining markers, both AQUA and QconCAT severely underestimated the toxin amounts. The tendency of the AQUA strategy to underestimate protein targets was seriously aggravated after the SDS-PAGE prefractionation. This was also true for QconCAT despite our SDS-PAGE-compatible design. Finally, only PSAQ standards gave reliable quantification after this prefractionation protocol. Even with the most powerful MS technologies, decomplexification often appears as a mandatory step before quantification of medium to low abundance proteins (10, 13). Actually, AQUA quantifications are often realized on prefractionated protein samples (6, 23). As illustrated in the present study, uncertainty on the yield of the target protein recovery due to these prefractionation steps can introduce important quantification biases that are efficiently corrected using PSAQ standards. This constitutes the major advantage of the PSAQ strategy over AQUA and QconCAT approaches.

Improvement of detection sensitivity was beyond the scope of the present study. Nevertheless, the staphylococcal superantigenic toxins could be detected at the picomolar level in water samples using our LC-QTOF instrumentation. A reliable quantification of toxins could be achieved down to 3.8 pM (i.e. 0.5 fmol equivalent to 10 pg of TSST-1 in the 120 µl sample analyzed). This limit was comparable regardless of the standardization procedure used, e.g. AQUA, QconCAT, or PSAQ, and is inherent to the QTOF performances. For comparison, a recently developed real-time immuno-PCR technique detected SEA toxin down to 6 pg/100 µl (i.e. 2 pM) that is reportedly 100 times more sensitive than previous commercial toxin detection ELISA (31). In urine, due to the complexity of the matrix, QconCAT and PSAQ standards allowed quantification of SEA and TSST-1 down to the nanomolar range (i.e. 44 fmol equivalent to 1.2 ng in the actual 100 µl sample analyzed). This compares favorably with a previous report on staphylococcal SEB enterotoxin MS-based quantification (32), in which the limit of quantification of SEB spiked in apple juice was estimated to be 50 ng/ml. Thus, despite a much higher protein complexity of human urine compared with apple juice, we demonstrated a lower quantification limit in this complex matrix. This can be partly attributed to the difference of sensitivity of the LC-MS instrumentation used. In the near future, we intend to improve the sensitivity of our quantification procedure through the use of multiple reaction monitoring (MRM). The discriminating power of MRM assays renders them especially suited to address the protein complexity and high dynamic range of biological fluids such as urine (10, 33, 34). The lower density of species detected in nano-LC-MRM runs should enhance the robustness of the PSAQ quantification method. On this respect, the opportunity to monitor different peptide standards offered by the PSAQ strategy can be a compelling advantage compared with single peptide strategies. Along the same line, when using single peptide standards, any sequence variation or post-translational modification in a marker peptide will dismiss quantification of the corresponding protein. The larger protein coverage allowed by the PSAQ strategy can also favor the detection and differential quantification of variant species of any protein of interest. It is a valuable feature when addressing the survey of potentially variable proteins such as staphylococcal superantigenic toxins (35).

Conclusion—
We have demonstrated the advantages of our PSAQ strategy over existing approaches for biomarker absolute quantification in complex samples, such as biological fluids. Considering the high sensitivity of MS analyses, a single medium-scale, cell-free protein expression experiment provides sufficient amounts of a given PSAQ standard for thousands of quantification analyses. Moreover, simple quality controls, such as SDS-PAGE, coupled to quantitative fluorescent detection can be performed whenever required. In this regard, as it was realized for nuclear magnetic resonance structural studies (36), we propose to initiate a community-based effort for the construction of large reference PSAQ libraries for protein biomarkers. This could extend the actual standardization initiatives of the proteomic community to the developing fields of biomarkers discovery and validation by enabling truly accurate quantitative proteomics (37).


    ACKNOWLEDGMENTS
 
We thank Michel Jaquinod and Myriam Ferro for helpful discussions, Charles Pineau and Regis Lavigne for MALDI-TOF analysis, Jean-Pierre Andrieu for AAA quantification of proteins, Christophe Masselon for smart advices and careful reading of the manuscript, Christophe Bruley for expert computer assistance, and Cedric Badiou for production of recombinant toxins.


   FOOTNOTES
 
Received, April 12, 2007, and in revised form, August 3, 2007.

Published, MCP Papers in Press, September 11, 2007, DOI 10.1074/mcp.M700163-MCP200

1 The abbreviations used are: AQUA, Absolute Quantification; AAA, amino acid analysis; MRM, multiple reaction monitoring; PSAQ, protein standard absolute quantification; QconCAT, concatemer of standard peptides for absolute quantification; SEA, staphylococcal enterotoxin A; SEB, staphylococcal enterotoxin B; TSST-1, toxic shock syndrome toxin-1. Back

* This work was supported by a grant from Sanofi-Aventis France and Bayer Pharma as part of a multi-organism call for proposals. Back

The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.

S The on-line version of this article (available at http://www.mcponline.org) contains supplemental material. Back

{ddagger}{ddagger} To whom corresponding should be addressed. Tel.: 334-38789657; Fax: 334-38785051; E-mail: virginie.brun{at}cea.fr


    REFERENCES
 TOP
 ABSTRACT
 EXPERIMENTAL PROCEDURES
 RESULTS
 DISCUSSION
 REFERENCES
 

  1. Aebersold, R. (2003 ) Constellations in a cellular universe. Nature 422, 115 –116[CrossRef][Medline]

  2. Lu, P., Vogel, C., Wang, R., Yao, X., and Marcotte, E. M. (2007 ) Absolute protein expression profiling estimates the relative contributions of transcriptional and translational regulation. Nat. Biotechnol. 25, 117 –124[CrossRef][Medline]

  3. Mallick, P., Schirle, M., Chen, S. S., Flory, M. R., Lee, H., Martin, D., Ranish, J., Raught, B., Schmitt, R., Werner, T., Kuster, B., and Aebersold, R. (2007 ) Computational prediction of proteotypic peptides for quantitative proteomics. Nat. Biotechnol. 25, 125 –131[CrossRef][Medline]

  4. Tai, S. S., Bunk, D. M., White, E. T., and Welch, M. J. (2004 ) Development and evaluation of a reference measurement procedure for the determination of total 3,3',5-triiodothyronine in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal. Chem. 76, 5092 –5096[Medline]

  5. Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., and Gygi, S. P. (2003 ) Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS. Proc. Natl. Acad. Sci. U. S. A., 100, 6940 –6945[Abstract/Free Full Text]

  6. Kirkpatrick, D. S., Gerber, S. A., and Gygi, S. P. (2005 ) The absolute quantification strategy: a general procedure for the quantification of proteins and post-translational modifications. Methods 35, 265 –273[CrossRef][Medline]

  7. Stemmann, O., Zou, H., Gerber, S. A., Gygi, S. P., and Kirschner, M. W. (2001 ) Dual inhibition of sister chromatid separation at metaphase. Cell 107, 715 –726[CrossRef][Medline]

  8. Barr, J. R., Maggio, V. L., Patterson, D. G., Jr., Cooper, G. R., Henderson, L. O., Turner, W. E., Smith, S. J., Hannon, W. H., Needham, L. L., and Sampson, E. J. (1996 ) Isotope dilution–mass spectrometric quantification of specific proteins: model application with apolipoprotein A-I. Clin. Chem. 42, 1676 –1682[Abstract/Free Full Text]

  9. Beynon, R. J., Doherty, M. K., Pratt, J. M., and Gaskell, S. J. (2005 ) Multiplexed absolute quantification in proteomics using artificial QCAT proteins of concatenated signature peptides. Nat. Methods 2, 587 –589[CrossRef][Medline]

  10. Anderson, L., and Hunter, C. L. (2006 ) Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins. Mol. Cell. Proteomics 5, 573 –588[Abstract/Free Full Text]

  11. Pratt, J. M., Simpson, D. M., Doherty, M. K., Rivers, J., Gaskell, S. J., and Beynon, R. J. (2006 ) Multiplexed absolute quantification for proteomics using concatenated signature peptides encoded by QconCAT genes. Nat. Protoc. 1, 1029 –1043[CrossRef][Medline]

  12. Rivers, J., Simpson, D. M., Robertson, D. H. L., Gaskell, S. J., and Beynon, R. J. (2007 ) Absolute multiplexed quantitative analysis of protein expression during muscle development using QconCAT. Mol. Cell. Proteomics 6, 1416 –1427[Abstract/Free Full Text]

  13. Shen, Y., Kim, J., Strittmatter, E. F., Jacobs, J. M., Camp, D. G., 2nd, Fang, R., Tolie, N., Moore, R. J., and Smith, R. D. (2005 ) Characterization of the human blood plasma proteome. Proteomics 5, 4034 –4045[CrossRef][Medline]

  14. McCormick, J. K., Yarwood, J. M., and Schlievert, P. M. (2001 ) Toxic shock syndrome and bacterial superantigens: an update. Annu. Rev. Microbiol. 55, 77 –104[CrossRef][Medline]

  15. Dinges, M. M., Orwin, P. M., and Schlievert, P. M. (2000 ) Exotoxins of Staphylococcus aureus. Clin. Microbiol. Rev. 13, 16 –34[Abstract/Free Full Text]

  16. Ferry, T., Thomas, D., Genestier, A. L., Bes, M., Lina, G., Vandenesch, F., and Etienne, J. (2005 ) Comparative prevalence of superantigen genes in Staphylococcus aureus isolates causing sepsis with and without septic shock. Clin. Infect. Dis. 41, 771 –777[CrossRef][Medline]

  17. Thomas, D., Chou, S., Dauwalder, O., and Lina, G. (2007 ) Diversity in Staphylococcus aureus Enterotoxins. Chem. Immunol. Allergy 93, 24 –41[Medline]

  18. Torizawa, T., Shimizu, M., Taoka, M., Miyano, H., and Kainosho, M. (2004 ) Efficient production of isotopically labeled proteins by cell-free synthesis: a practical protocol. J. Biomol. NMR 30, 311 –325[CrossRef][Medline]

  19. Nishihara, J. C., and Champion, K. M. (2002 ) Quantitative evaluation of proteins in one- and two-dimensional polyacrylamide gels using a fluorescent stain. Electrophoresis 23, 2203 –2215[CrossRef][Medline]

  20. Jaquinod, M., Villiers, F., Kieffer-Jaquinod, S., Hugouvieux, V., Bruley, C., Garin, J., and Bourguignon, J. (2007 ) A proteomics dissection of Arabidopsis thaliana vacuoles isolated from cell culture. Mol. Cell. Proteomics 6, 394 –412[Abstract/Free Full Text]

  21. Kigawa, T., Muto, Y., and Yokoyama, S. (1995 ) Cell-free synthesis and amino acid-selective stable isotope labeling of proteins for NMR analysis. J. Biomol. NMR 6, 129 –134[Medline]

  22. Taussig, M. J., Stoevesandt, O., Borrebaeck, C. A., Bradbury, A. R., Cahill, D., Cambillau, C., de Daruvar, A., Dubel, S., Eichler, J., Frank, R., Gibson, T. J., Gloriam, D., Gold, L., Herberg, F. W., Hermjakob, H., Hoheisel, J. D., Joos, T. O., Kallioniemi, O., Koegl, M., Konthur, Z., Korn, B., Kremmer, E., Krobitsch, S., Landegren, U., van der Maarel, S., McCafferty, J., Muyldermans, S., Nygren, P. A., Palcy, S., Pluckthun, A., Polic, B., Przybylski, M., Saviranta, P., Sawyer, A., Sherman, D. J., Skerra, A., Templin, M., Ueffing, M., and Uhlen, M. (2007 ) ProteomeBinders: planning a European resource of affinity reagents for analysis of the human proteome. Nat. Methods 4, 13 –17[CrossRef][Medline]

  23. Rifai, N., Gillette, M. A., and Carr, S. A. (2006 ) Protein biomarker discovery and validation: the long and uncertain path to clinical utility. Nat. Biotechnol. 24, 971 –983[CrossRef][Medline]

  24. Ong, S. E., and Mann, M. (2005 ) Mass spectrometry-based proteomics turns quantitative. Nat. Chem. Biol. 1, 252 –262[CrossRef][Medline]

  25. Wei, H., Nolkrantz, K., Parkin, M. C., Chisolm, C. N., O’Callaghan, J. P., and Kennedy, R. T. (2006 ) Identification and quantification of neuropeptides in brain tissue by capillary liquid chromatography coupled off-line to MALDI-TOF and MALDI-TOF/TOF-MS. Anal. Chem. 78, 4342 –4351[Medline]

  26. Barnidge, D. R., Goodmanson, M. K., Klee, G. G., and Muddiman, D. C. (2004 ) Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-MS/MS using protein cleavage and isotope dilution mass spectrometry. J. Proteome. Res. 3, 644 –652[CrossRef][Medline]

  27. Cheng, D., Hoogenraad, C. C., Rush, J., Ramm, E., Schlager, M. A., Duong, D. M., Xu, P., Wijayawardana, S. R., Hanfelt, J., Nakagawa, T., Sheng, M., and Peng, J. (2006 ) Relative and absolute quantification of postsynaptic density proteome isolated from rat forebrain and cerebellum. Mol. Cell. Proteomics. 5, 1158 –1170[Abstract/Free Full Text]

  28. Muchmore, D. C., McIntosh, L. P., Russell, C. B., Anderson, D. E., and Dahlquist, F. W. (1989 ) Expression and nitrogen-15 labeling of proteins for proton and nitrogen-15 nuclear magnetic resonance. Methods Enzymol. 177, 44 –73.[Medline]

  29. Vinarov, D. A., Lytle, B. L., Peterson, F. C., Tyler, E. M., Volkman, B. F., and Markley, J. L. (2004 ) Cell-free protein production and labeling protocol for NMR-based structural proteomics. Nat. Methods 1, 149 –153[CrossRef][Medline]

  30. Kuhn, E., Wu, J., Karl, J., Liao, H., Zolg, W., and Guild, B. (2004 ) Quantification of C-reactive protein in the serum of patients with rheumatoid arthritis using multiple reaction monitoring mass spectrometry and 13C-labeled peptide standards. Proteomics 4, 1175 –1186[CrossRef][Medline]

  31. Fischer, A., von Eiff, C., Kuczius, T., Omoe, K., Peters, G., and Becker, K. (2007 ) A quantitative real-time immuno-PCR approach for detection of staphylococcal enterotoxins. J. Mol. Med. Epub ahead of print.

  32. Callahan, J. H., Shefcheck, K. J., Williams, T. L., and Musser, S. M. (2006 ) Detection, confirmation, and quantification of staphylococcal enterotoxin B in food matrixes using liquid chromatography–mass spectrometry. Anal. Chem. 78, 1789 –1800[Medline]

  33. Domon, B., and Aebersold, R. (2006 ) Mass spectrometry and protein analysis. Science 312, 212 –217[Abstract/Free Full Text]

  34. Unwin, R. D., Griffiths, J. R., Leverentz, M. K., Grallert, A., Hagan, I. M., and Whetton, A. D. (2005 ) Multiple reaction monitoring to identify sites of protein phosphorylation with high sensitivity. Mol. Cell. Proteomics 4, 1134 –1144[Abstract/Free Full Text]

  35. Thomas, D. Y., Jarraud, S., Lemercier, B., Cozon, G., Echasserieau, K., Etienne, J., Gougeon, M. L., Lina, G., and Vandenesch, F. (2006 ) Staphylococcal enterotoxin-like toxins U2 and V, two new staphylococcal superantigens arising from recombination within the enterotoxin gene cluster. Infect. Immun. 74, 4724 –4734[Abstract/Free Full Text]

  36. Stevens, R. C., Yokoyama, S., and Wilson, I. A. (2001 ) Global efforts in structural genomics. Science 294, 89 –92[Abstract/Free Full Text]

  37. Mischak, H. A. R., Banks, R. E., Conaway, M., Coon, J., Dominiczak, A., Ehrich, J. H. H., Fliser, D., Girolami, M., Hermjakob, H., Hochstrasser, D., Jankowski, J., Julian, B. A., Kolch, W., Massy, Z. A., Neusuess, C., Novak, J., Peter, K., Rossing, K., Schanstra, J., Semmes, O. J., Theodorescu, D., Thongboonkerd, V., Weissinger, E. M., Van Eyk, J.E., and Yamamoto, T. (2007 ) Clinical proteomics: a need to define the field and to begin to set adequate standards. Proteomics Clin. Appl. 1, 148 –156[CrossRef]


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Mol. Cell. ProteomicsHome page
T. Fortin, A. Salvador, J. P. Charrier, C. Lenz, X. Lacoux, A. Morla, G. Choquet-Kastylevsky, and J. Lemoine
Clinical Quantitation of Prostate-specific Antigen Biomarker in the Low Nanogram/Milliliter Range by Conventional Bore Liquid Chromatography-Tandem Mass Spectrometry (Multiple Reaction Monitoring) Coupling and Correlation with ELISA Tests
Mol. Cell. Proteomics, May 1, 2009; 8(5): 1006 - 1015.
[Abstract] [Full Text] [PDF]


Home page
Brief Funct Genomic ProteomicHome page
Y. Gao, R. D. Holland, and L.-R. Yu
Quantitative proteomics for drug toxicity
Brief Funct Genomic Proteomic, April 7, 2009; (2009) elp006v1.
[Abstract] [Full Text] [PDF]


Home page
Brief Funct Genomic ProteomicHome page
X. Ye, J. Blonder, and T. D. Veenstra
Targeted proteomics for validation of biomarkers in clinical samples
Brief Funct Genomic Proteomic, March 1, 2009; 8(2): 126 - 135.
[Abstract] [Full Text] [PDF]


Home page
Appl. Environ. Microbiol.Home page
J.-A. Hennekinne, V. Brun, M.-L. De Buyser, A. Dupuis, A. Ostyn, and S. Dragacci
Innovative Application of Mass Spectrometry for the Characterization of Staphylococcal Enterotoxins Involved in Food Poisoning Outbreaks
Appl. Envir. Microbiol., February 1, 2009; 75(3): 882 - 884.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow All Versions of this Article:
M700163-MCP200v1
6/12/2139    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Glossary
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brun, V.
Right arrow Articles by Garin, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brun, V.
Right arrow Articles by Garin, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 All ASBMB Journals   Journal of Biological Chemistry 
 Journal of Lipid Research   ASBMB Today 
Advertisement
spacer
Advertisement
Advertisement