|
Advertisement | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Molecular & Cellular Proteomics 8:1921-1933, 2009.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ABSTRACT |
|---|
|
|
|---|
-carboxymethyllysine (CML) and pentosidine from 58 AMD and 32 control donors. CML and pentosidine are advanced glycation end products that are abundant in Bruch membrane, the extracellular matrix separating the retinal pigment epithelium from the blood-bearing choriocapillaris. We measured CML and pentosidine by LC-MS/MS and LC-fluorometry, respectively, and found higher mean levels of CML (
54%) and pentosidine (
64%) in AMD (p < 0.0001) relative to normal controls. Plasma protein fructosyl-lysine, a marker of early glycation, was found by amino acid analysis to be in equal amounts in control and non-diabetic AMD donors, supporting an association between AMD and increased levels of CML and pentosidine independent of other diseases like diabetes. Carboxyethylpyrrole (CEP), an oxidative modification from docosahexaenoate-containing lipids and also abundant in AMD Bruch membrane, was elevated
86% in the AMD cohort, but autoantibody titers to CEP, CML, and pentosidine were not significantly increased. Compellingly higher mean levels of CML and pentosidine were present in AMD plasma protein over a broad age range. Receiver operating curves indicate that CML, CEP adducts, and pentosidine alone discriminated between AMD and control subjects with 78, 79, and 88% accuracy, respectively, whereas CML in combination with pentosidine provided
89% accuracy, and CEP plus pentosidine provided
92% accuracy. Pentosidine levels appeared slightly altered in AMD patients with hypertension and cardiovascular disease, indicating further studies are warranted. Overall this study supports the potential utility of plasma protein CML and pentosidine as biomarkers for assessing AMD risk and susceptibility, particularly in combination with CEP adducts and with concurrent analyses of fructosyl-lysine to detect confounding factors.
There is growing consensus that AMD is an age-related inflammatory disease involving dysregulation of the complement system; however, triggers of the inflammatory response have yet to be well defined. Oxidative stress appears to be involved as smoking significantly increases the risk of AMD (2), antioxidant vitamins can selectively slow AMD progression (3), and a host of oxidative protein and DNA modifications have been detected at elevated levels in AMD Bruch membrane, drusen, retina, RPE, and plasma (4–11). Oxidative protein modifications like carboxyethylpyrrole (CEP) and N
-carboxymethyllysine (CML), both elevated in AMD Bruch membrane, stimulate neovascularization in vivo (12, 13), suggesting possible roles in CNV. Other studies have shown that mice immunized with CEP protein modifications develop an AMD-like phenotype (14). Accordingly oxidative modifications may be catalysts or triggers of AMD pathology (6).
AMD has long been hypothesized to be a systemic disease (15) based in part on the presence of retinal drusen in patients with membranoproliferative glomerulonephritis type II (16) and systemic complement activation in AMD (17). Support for this hypothesis also comes from mounting evidence that advanced glycation end products (AGEs) may play a role in AMD (4, 5, 7, 18, 19). AGEs are a heterogeneous group of mostly oxidative modifications resulting from the Maillard nonenzymatic glycation reaction that have been associated with age-related diseases and diabetic complications (20, 21). In 1998, CML was the first AGE to be found in AMD Bruch membrane and drusen (4). Other AGEs have since been detected in AMD ocular tissues (5, 7, 18) and in Bruch membrane, drusen, RPE, and choroidal extracellular matrix from healthy eyes (6, 22). CML, a nonfluorescent AGE, and pentosidine, a fluorescent cross-linking AGE, increase with age in Bruch membrane (18, 23). Receptors for AGEs (RAGE and AGE-R1) appear elevated on RPE and photoreceptor cells in early and advanced dry AMD (7) especially in RPE overlying drusen-like deposits on Bruch membrane (19). AGE-R3, also known as galectin-3, is elevated in AMD Bruch membrane (24).
Although AMD susceptibility genes now account for over 50% of AMD cases (25), many individuals with AMD risk genotypes may never develop advanced disease with severe vision loss. Nevertheless the prevalence of advanced AMD is increasing (26). Toward the discovery of better methods to detect those at risk for advanced AMD, we quantified CML and pentosidine in plasma proteins from AMD and control patients and compared their discriminatory accuracy with plasma CEP biomarkers. CEP biomarkers have been shown to enhance the AMD predictive accuracy of genomic AMD biomarkers (11). This report shows CML and pentosidine to be elevated in AMD plasma proteins and demonstrates their potential biomarker utility in assessing AMD risk and susceptibility especially in combination with CEP biomarkers.
| EXPERIMENTAL PROCEDURES |
|---|
|
|
|---|
|
Sample Preparation and Amino Acid Analysis
Plasma (
200 µl;
10-mg protein) was transferred to 6 x 50-mm glass hydrolysis tubes, and protein was precipitated with 2 volumes of cold acetone. After incubation at 4 °C for 10–20 min, the preparation was centrifuged briefly in a Microfuge, the supernatant was discarded, and the pellet was washed once with 67% acetone (400 µl) and vacuum-dried (27). Plasma protein was prepared for hydrolysis by adding 60 µl of 6 N HCl to each dried pellet, and then the hydrolysis tubes were placed in a 40-ml screw cap vial containing
300 µl of 6 N HCl with a few small crystals of phenol. The 40-ml vial was capped with a Mininert slide valve, the valve was connected to a vacuum pump and argon source via a three-way stopcock, and the vial was alternately evacuated and flushed with argon three times and then sealed under vacuum (27). Protein was hydrolyzed at 110 °C for 16 h, then vacuum-dried, flushed with argon, and stored at –20 °C until analysis. Protein was quantified by PTC amino acid analysis (
80 µg was derivatized, and
3 µg was analyzed) using an Agilent 1100 HPLC system, a Haisil PTC C18 column (220 x 2.1 mm; Applied Biosystems), and a Gilson model 116 UV detector (27). Protein was also quantified by AccQ·TagTM amino acid analysis (
3.5 µg was derivatized, and
35 ng was analyzed) using an Acquity Ultra Performance LC system (Waters) and AccQ·Tag Ultra column (100 x 2.1 mm) according to the vendor (28). Bovine serum albumin from the National Bureau of Standards was used as a protein standard and hydrolysis control. Amino acid calibration standards were obtained from Pierce and Thermo Scientific.
Fructosyl-lysine Quantification
Fructosyl-lysine was quantified as furosine derivative (
-N-(2-furoylmethyl)lysine) by duplicate AccQ·Tag amino acid analyses (
15 µg was derivatized, and
2.7 µg was analyzed) using the Acquity LC system (Waters) described above. Furosine contains a primary and a secondary amino group, and both are derivatized by the AccQ·Tag reagent, yielding two different monoderivatized forms and a diderivatized species. The apparent diderivatized species was well separated from other amino acids, exhibited a constant response factor up to
55 pmol derivatized, and was used for quantification of furosine in protein hydrolysates. Furosine standard was purchased from NeoMPS, Inc.
CML and Pentosidine Quantification
Plasma protein HCl hydrolysates (
8 mg in 40 µl of H2O) were spiked with a S-β(4-pyridylethyl)-L-cysteine (PEC) internal standard (50 pmol) and fractionated on LC system 1 composed of an Agilent 1100 HPLC system, a HypercarbTM porous graphite carbon column (5-µm particles, 50 x 10 mm; Thermo Scientific) maintained at 30 °C with an Applied Biosystems 112A column oven, and aqueous trifluoroacetic acid/acetonitrile solvents using gradient elution (0–100% acetonitrile over 13 min) and a flow rate of 1 ml/min. The eluant was monitored for fluorescence (335-nm excitation, 385-nm emission) with a WatersTM 474 scanning fluorometer and initially split with 20% directed to an API 3000 triple quadrupole electrospray mass spectrometer (Applied Biosystems) and 80% directed to a fraction collector. After determining reproducible elution times using control plasma spiked with standard AGEs and PEC, 100% of the eluant was directed to the fraction collector and three fractions were collected, one each for CML, PEC, and the co-eluting pentosidine plus argpyrimidine. The fractions were vacuum dried and re-fractionated on LC system 2 composed of the same HPLC equipment but with an aqueous normal phase Cogent Diamond HydrideTM Column (4.2 µm particles, 150 x 2.1 mm) used at room temperature. Fractions containing CML were re-chromatographed using aqueous acetic acid/acetonitrile solvents and gradient elution (95–0% acetonitrile in 13.6 min) at a flow rate of 400 µl/min. Fractions containing PEC, argpyrimidine and pentosidine were re-chromatographed using 10 mM ammonium acetate, pH 6.0/acetonitrile solvents, gradient elution (100–0% acetonitrile in 15 min) at a flow rate of 400 µl/min. Aqueous normal phase chromatography was monitored by fluorescence detection followed by 100% of the eluant directed to the mass spectrometer. CML and PEC were quantified by multiple reaction monitoring (MRM), and pentosidine and argpyrimidine were measured by fluorescence; final CML and pentosidine amounts were adjusted based on the recovery of the PEC internal standard. Plasma protein argpyrimidine concentrations were below reliable detection limits in this analytical system and are not reported. Calibration curves were developed in triplicate each day of analysis using LC system 2 and external standards. CML standard was purchased from NeoMPS, Inc., pentosidine was obtained from the International Maillard Reaction Society (Case Western Reserve University, Cleveland, OH), argpyrimidine was prepared in our laboratories by R. H. N., and PEC was purchased from Sigma.
Mass Spectrometry
The mass spectrometer was operated with Analyst 1.4.1 software (Applied Biosystems); MS/MS spectra were generated on singly charged precursor ions for CML, pentosidine, argpyrimidine, and PEC; and specific transition ions for each modified amino acid were analyzed by MRM. The declustering potential, focusing potential, collision energy, and exit potential were optimized for each ion to ±0.1 Da and ±1 V. Ion spray voltage was set at 5300 V, and source temperature was set at 425 °C in LC system 1 and at 490 °C in LC system 2. The m/z of the precursor ions and each of the transitions ions and their optimized voltages were transcribed, respectively, into an LCsync method in the Analyst 1.4.1 software. CML was quantified by MRM using precursor ion 205.1 and product ion 84.1, PEC was quantified using precursor ion 227.3 and product ion 106.1, pentosidine was monitored by MRM using precursor ion 379.2 and product ion 187.2, and argpyrimidine was monitored using precursor ion 255.2 and product ion 237.3. Peak areas and external standard calibration curves were used for quantification of CML and PEC by MRM and of pentosidine by fluorescence.
Pentosidine and CML Autoantibody Assays
Pentosidine autoantibody titers were measured by direct ELISA using pentosidine conjugated to bovine serum albumin (pentosidine-BSA) or unmodified BSA as the coating antigen (
8 µg/well). CML autoantibody titers were measured with the same methodology using CML-BSA or BSA as the coating agent (
15 µg/well). Plasma (100 µl of a 1:10 dilution) was applied to coating agents, and the ELISA was developed as described previously for the CEP autoantibody assay (9, 11). Anti-CML (R&D Systems product MAB3247) or anti-pentosidine monoclonal antibodies (Trans Genic Inc. product KH012) were used for positive ELISA controls. Titer was defined as the ratio of plasma binding to antigen (A) versus binding to BSA (A0) (9).
Preparation of AGE-BSA
Pentosidine-BSA was prepared by mixing pentosidine (1 mg; NeoMPS, Inc. product SC1535) in dimethylformamide (100 µl) with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide HCl (5 mg; Pierce) and N-hydroxysuccinimide (6 mg; Pierce) at room temperature for 2 h followed by the addition of BSA (2.5 mg in 0.5 ml PBS; Sigma product A6003) and continued incubation at 37 °C for 48 h. The reaction was stopped by dialysis against 25 mM Tris-HCl (pH 8.0) for 2 h at 4 °C and then dialysis against PBS for another 24 h with two changes. CML-BSA was prepared by mixing BSA in PBS with 25 mM glyoxylic acid and 50 mM NaCNBH3 for 48 h at room temperature followed by dialysis against PBS for 24 h with two changes (29). Protein was quantified by the BCA assay (Pierce), and pentosidine and CML modifications were confirmed by Western analysis before and after the modification reactions using anti-CML monoclonal antibody (R&D Systems product MAB3247) or anti-pentosidine monoclonal antibody (Trans Genic Inc. product KH012).
CEP Adduct and CEP Autoantibody Assays
The CEP adduct and autoantibody concentrations of plasma used in this study were reported previously among 1404 plasma samples (11). Briefly CEP adducts were quantified with a competitive ELISA using rabbit anti-CEP polyclonal antibody, CEP conjugated to BSA as coating agent, and known amounts of CEP-modified human serum albumin as reference protein. CEP autoantibody titers were measured by direct ELISA using CEP-BSA as coating antigen. These methods are well documented (9, 11).
Statistics
Continuous measures were summarized using means, standard deviations, medians, and interquartile ranges, whereas categorical factors were described using frequencies and percentages. Differences between control and AMD patients in plasma concentrations of CML, pentosidine, and CEP adducts as well as in CML, pentosidine, and CEP autoantibodies were evaluated using two-sample t tests in Excel 2003 (Microsoft® Office). To evaluate a relationship between CML and pentosidine with AMD susceptibility, a logistic regression model was fit with both variables as predictors using SAS 9.1 software (SAS Institute). C-statistics measured the ability of the model to discriminate between AMD and controls, and odds ratios (ORs) showed the change in risk of AMD based on the predictors. ORs, c-statistics, and p values were determined based on log-transformed marker concentrations. Validation of c-statistics was performed using 2000 bootstrap (random) resamplings to calculate empirical 95% confidence intervals (CIs) and by performing 10-fold cross-validation. Sensitivity and specificity were calculated to maximize the sum of the two values using receiver operating characteristic (ROC) curves constructed with SAS 9.1 from the output of logistic regression analysis fit with either CML, pentosidine, or CEP adducts alone or in combination. C-statistics and p values comparing ROC curves were determined with SAS 9.1. For association analyses of combined effects of CML and pentosidine with CEP adducts, ORs with 95% CI and Fisher exact p values were also calculated with SAS 9.1 software. Pearson's correlation analysis in Minitab Release 15 (Minitab Inc.) was used to compare concentrations of AGE markers with plasma donor age.
| RESULTS |
|---|
|
|
|---|
Plasma from a total of 32 control subjects and 58 AMD patients was analyzed, including 27 early/mid-stage dry AMD and 31 advanced AMD patients. Protein was quantified by both PTC and AccQ·Tag amino acid analysis, yielding well defined protein concentrations with excellent agreement between the amino acid analysis methods (<4% average difference). Amounts of CML and pentosidine in each HCl hydrolysate were corrected based on the percent recovery of the PEC internal standard that averaged 70.1 ± 12.4 (mean ± S.D., n = 90). Overall AMD patients exhibited
54% higher CML and
64% higher pentosidine concentrations relative to control plasma (Fig. 1, A and B, and Table II). Comparison of log-transformed values confirmed the results with p < 0.0001 for both AGEs. Mean variability averaged
36% relative standard deviation (R.S.D.) for CML and
24% R.S.D. for pentosidine (n = 90). Relative to early/mid-stage AMD, advanced AMD patients exhibited
9% higher CML (p = 0.35) and
17% higher pentosidine (p = 0.06) (Table II). CML and pentosidine autoantibody titers measured by ELISA were
9–11% higher in AMD patients; however, these differences were not statistically significant (Fig. 1, C and D).
|
|
6.3 for CML and OR
10.6 for pentosidine; ORs for advanced AMD were greater than for early/mid-stage disease. Each OR exhibited a large CI (Table II), indicating that these are preliminary estimates that lack precision.
|
86% higher (p < 0.0001), but mean CEP autoantibodies were not significantly higher in AMD plasma (p = 0.84) (Fig. 2, A and B). CEP autoantibody titers were higher than CML and pentosidine autoantibody titers in the AMD cohort, but none were significantly elevated relative to the control cohort. Correlation of CEP adducts with CML and pentosidine (Fig. 2, C and D) shows that all three oxidative protein modifications were elevated 69–74% above median control levels. Predicted risk of AMD yielded OR = 13.9 (95% CI, 4.9, 39.7) for pentosidine plus CML, OR = 20.1 (95% CI, 6.5, 62.2) for CML plus CEP adducts, and OR = 5.7 (95% CI, 2.2, 14.9) for pentosidine plus CEP adducts. Again the large confidence intervals indicate that the ORs are elevated but lack precision.
|
78%) and CML (
79%) alone (p
0.90) and between pentosidine and CEP alone (p
0.10); however, pentosidine exhibited significantly higher discrimination accuracy (
88%) than CML (p
0.05). c-statistics for the joint effect of combined markers were verified by bootstrap resampling and by 10-fold cross-validation. Comparison of c-statistics for combined markers suggested no significant difference in discriminatory accuracy between CEP plus CML (
87%) versus either marker alone (p
0.1) or between CEP plus pentosidine (
92%) versus pentosidine alone (p
0.2). However, CEP plus pentosidine appeared to be a better discriminator than CEP alone (p
0.02), and CML plus pentosidine (
89%) may be a better discriminator than CEP alone (p
0.06). These results suggest that the use of all three biomarkers may provide the best approach to a prognostic test for AMD.
|
|
|
1.7%; n = 90). The average concentration of plasma protein furosine was 1.03 ± 0.11 pmol/µg in normal controls (n = 32), 1.03 ± 0.09 pmol/µg in non-diabetic AMD donors (n = 53), and 1.24 ± 0.05 pmol/µg in previously diagnosed diabetic AMD patients (n = 5). No difference was found in mean furosine concentrations between controls and non-diabetic AMD patients; however, the five diabetic AMD donors exhibited
20% higher furosine levels than the controls.
|
| DISCUSSION |
|---|
|
|
|---|
The purpose of this study was to discover biomarkers for assessing AMD risk and susceptibility. We hypothesized that CML and pentosidine could be elevated in plasma proteins based on similar histological localization of CML, pentosidine, and CEP in Bruch membrane and drusen and the fact that CEP adducts are elevated in AMD plasma (11). Other direct evidence of oxidative damage in AMD tissues in addition to CML (4) and CEP (6, 9, 11) includes elevated levels of glycoaldehyde-derived AGEs in the RPE and photoreceptor cells in early and advanced dry AMD (7); 4-hydroxynonenal, acrolein, nitrotyrosine, and the DNA modification 8-hydroxy-2'-deoxyguanosine in advanced dry AMD retina (8); and nitrotyrosine in AMD plasma (10). Recently fluorescent AGEs were elegantly demonstrated in human RPE, Bruch membrane, and choroidal extracellular matrix, and RPE grown in vitro on AGEs was shown to contain increased lipofuscin (39), which accumulates in AMD with potential adverse consequences (40). Notably RAGE belongs to the family of multiligand, pattern recognition receptors associated with AMD pathology (41–47) and appears to mediate AGE-induced damage of RPE cells in vitro (7) and of neurons in vivo (48).
In the present study of 58 AMD and 32 control subjects, we found mean CML and pentosidine to be significantly elevated in AMD plasma proteins over a broad age range and in those with early/mid-stage dry AMD. Comparison of early/mid-stage AMD with advanced AMD donors revealed no significant difference in CML concentrations; however, the average pentosidine plasma protein level was
17% higher in advanced AMD (p
0.06), suggesting that analysis of larger cohorts could reveal a significant difference with disease progression. Mean CEP adducts were elevated 86% in the AMD cohort (p < 0.0001), but autoantibody titers for CEP, CML, and pentosidine were not elevated significantly. The CEP autoantibody results differ from our previous report (11) where mean levels were elevated
30% (p < 0.0001). This discrepancy is due in part to sample size, which was smaller in the present study (n = 86) compared with the previous study (n = 1404), and in part to the variability associated with the autoantibody ELISA procedure. The present analyses detected no confounding influences regarding CML plasma protein concentrations; however, pentosidine levels were significantly higher in AMD donors with hypertension or cardiovascular disease as found previously for CEP adducts (11). Epidemiological studies have inconsistently associated hypertension and cardiovascular disease with AMD (49). This preliminary analysis involved relatively small AMD and control cohorts, and further studies are warranted of demographic and health factor influences and CML and pentosidine autoantibody levels.
We quantified furosine, an acid hydrolysis product of fructosyl-lysine, because of its association with diabetic complications and other diseases (34–36). Control and non-diabetic AMD plasma protein samples exhibited mean furosine concentrations of
1.0 pmol/µg of protein in excellent agreement with reported values for non-diabetic plasma, i.e. 0.9–1.0 pmol of furosine/µg of protein (34–36). Except for five diagnosed diabetic AMD donors with mean furosine of 1.24 pmol/µg, no other donor in the study population exhibited furosine >2 S.D. above the mean control level (i.e. >1.25 pmol/µg). Arguably furosine concentrations within 1 S.D. of the mean diabetic level (i.e.
1.19 pmol/µg) might be suspect diabetics, and five donor plasma samples in our study group fit this criteria. For these three control and two AMD patients, CML and pentosidine concentrations were <1 S.D. from the mean control or AMD level, respectively, and medical records provided no indication that they were diabetics. These five plasma samples also did not exhibit significantly altered CEP adduct levels, consistent with our previous finding (11) that CEP adducts are not elevated in AMD diabetic compared with AMD non-diabetic plasma (from the analysis of 796 diabetic and 130 non-diabetic AMD donors). Overall the furosine analyses showed no unknown diabetics were present in the study population and support an association between AMD pathology and increased levels of plasma protein CML and pentosidine.
The present results compellingly demonstrated higher CML and pentosidine levels in AMD plasma proteins; therefore their potential AMD biomarker efficacy was compared with each other and with CEP adducts. Odds ratios for AMD risk based on elevated CML (OR, 6.3; 95% CI, 2.3, 17.3) and pentosidine (OR; 10.6; 95% CI, 3.4, 33.5) for all AMD cases suggest that CML and pentosidine offer prognostic potential. However, the large confidence intervals indicate that more analyses are required to refine precision. Nevertheless these OR estimates were greater than the OR based on elevated CEP adducts (OR, 3.4; 95% CI, 1.3, 9.0). For comparison, elevated CEP adducts and CEP autoantibodies combined yielded an OR of 3.2 (95% CI, 2.5, 4.0) for AMD risk in a larger study population (n = 1404) (11). The area under the ROC curves (c-statistics) suggest that CML and CEP adducts alone can discriminate between AMD and control plasma donors with approximately equal accuracy (
78–79%) and that pentosidine alone can discriminate with higher accuracy (88%). C-statistics for joint effect were increased relative to the single markers with significant differences associated with pentosidine plus CEP, a combination with better discrimination accuracy than CEP alone (p
0.02), and possibly with CML plus pentosidine (
89%), a combination that also may be a better discriminator than CEP alone (p
0.06). Nevertheless all three markers may offer the most accurate assessment of AMD risk.
For clinical usefulness, standardization of AGE measurements is needed. Although pentosidine and CML are well studied, comparison of AGE results across multiple studies remains complicated by variations in sample preparation, specimen storage, AGE assay methods, protein quantification methods, and the array of formats used to report quantitative AGE data (e.g. pmol/ml, pmol/mg of protein, fmol/nmol of Lys, and mmol/mol of hydroxyproline, among others). In this study, the variability of the LC-MS and LC-fluorometry measurements for CML and pentosidine (
36 and
24% R.S.D., respectively) was significantly lower than the variability of ELISA measurements for CEP adducts (
50–52% R.S.D.) (11). The variability of ELISA-measured autoantibody titers for CML, pentosidine, and CEP (11) was even greater (51–67% R.S.D.) perhaps due in part to plasma storage time (i.e. 4–34 months) and possible antibody inactivation. In this study, storage at –80 °C under argon in the presence of butylated hydroxytoluene antioxidant probably had little impact on CML and pentosidine because immediately upon thawing the plasma protein was precipitated, washed, and hydrolyzed. Protein was quantified by amino acid analysis using two methods, yielding <4% average difference in amount per method and <5% average R.S.D. per sample. Toward improved methodological standardization, we suggest the use of chromatographic rather than ELISA methods to measure AGEs and the expanded use of amino acid analysis to quantify protein and furosine.
Overall this study supports the hypothesis that AMD is a systemic disease (15, 17) and demonstrates the potential utility of plasma protein CML and pentosidine as biomarkers for AMD risk or susceptibility, particularly in combination with CEP. The statistical analyses suggest that plasma levels of CML together with pentosidine discriminate between AMD and control patients with 89% accuracy and that pentosidine in combination with CEP adducts can discriminate with 92% accuracy. However, factors potentially confounding plasma protein CML and pentosidine as AMD biomarkers should not be ignored. Concurrent monitoring of plasma protein furosine provides an effective method to narrow the cause of increased AGEs. When furosine, CML, and pentosidine are all elevated, an accurate clinical assessment will require more information. In such cases, CEP adduct levels could help rule out diabetic complications because plasma CEP adducts are elevated in AMD but not in diabetes (11). The present results warrant a much larger investigation, both prospective and longitudinal, of clinical applications of plasma protein CML, pentosidine, and CEP as AMD biomarkers.
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
* This work was supported, in whole or in part, by National Institutes of Health Grants EY015638, EY014239, and EY09912. This work was also supported by State of Ohio Grant BRTT 05-29, a Foundation Fighting Blindness center grant (to the Cole Eye Institute), a Research to Prevent Blindness (RPB) challenge grant (to the Cole Eye Institute), a RPB senior investigator award (to J. W. C.), a Steinbach Award (to J. W. C.), and the Cleveland Clinic Foundation. ![]()
The on-line version of this article (available at http://www.mcponline.org) contains supplemental material. ![]()
1 The abbreviations used are: AMD, age-related macular degeneration; AGE, advanced glycation end product; AccQ, 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate; CEP, carboxyethylpyrrole; CI, confidence interval; CML, N
-carboxymethyllysine; CNV, choroidal neovascularization; OR, odds ratio; PEC, S-β(4-pyridylethyl)-L-cysteine; PTC, phenylthiocarbamyl; ROC, receiver operating characteristic; RPE, retinal pigment epithelium; R.S.D., relative S.D.; RAGE and AGE-R, receptors for AGEs; MRM, multiple reaction monitoring..

A consultant for Alcon Research Ltd. and Allergan, Inc. and holds a patent for CEP biomarker technology licensed to Frantz Biomarkers, LLC. To whom correspondence should be addressed: Cole Eye Inst., Cleveland Clinic Foundation (i-31), 9500 Euclid Ave., Cleveland, OH 44195. Tel.: 216-445-0425; Fax: 216-445-3670; E-mail: Crabbj{at}ccf.org.
| REFERENCES |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| All ASBMB Journals | Journal of Biological Chemistry |
| Journal of Lipid Research | ASBMB Today |