MCP
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


A more recent version of this article appeared on May 1, 2008.
This Article
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow All Versions of this Article:
M700293-MCP200v1
7/5/962    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Glossary
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Brosch, M.
Right arrow Articles by Choudhary, J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brosch, M.
Right arrow Articles by Choudhary, J.

Submitted on June 25, 2007
Revised on January 10, 2008
Accepted on January 23, 2008

Comparison of mascot and X!tandem performance for low and high accuracy mass spectrometry and the development of an adjusted mascot threshold

Markus Brosch, Sajani Swamy, Tim Hubbard, and Jyoti Choudhary

The Wellcome Trust Sanger Institute, Cambridge CB10 1SA

Corresponding Author: jc4{at}sanger.ac.uk

It is a major challenge to develop effective sequence database search algorithms to translate molecular weight and fragment mass information obtained from tandem mass spectrometry into high quality peptide and protein assignments. We investigated the peptide identification performance of Mascot and X!Tandem for mass tolerance settings common for low and high accuracy mass spectrometry. We demonstrate that sensitivity and specificity of peptide identification can vary substantially for different mass tolerance settings, but this effect is more significant for Mascot. We present an Adjusted Mascot Threshold, which allows the user to freely select the best trade-off between sensitivity and specificity. The Adjusted Mascot Threshold was compared with the default Mascot and X!Tandem scoring thresholds and shown to be more sensitive at the same false discovery rates, for both low and high accuracy mass spectrometry data.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 All ASBMB Journals   Journal of Biological Chemistry 
 Journal of Lipid Research   ASBMB Today 
Copyright © 2008 by the American Society for Biochemistry and Molecular Biology.